Cooper Lighting AMETRIX SRR Installation Instructions page 2

Semi-recessed fixtures

Advertisement

Semi-recessed fixtures shown without thermal protectors
Vault w/ visor
These installation instructions are valid with the above Ametrix styles.
Securing fixture to ceiling tile
2.
#10-32 x3/8"
Pan head screw
Universal
(4x)
bracket
1.
If possible, remove ceiling tile from grid to facilitate fixture
installation.
2.
Using cut out dimensions provided on page four(4), cut
appropriate size opening in ceiling tile.
3.
Insert fixture assembly into cut out in ceiling tile.
3.
Replacing brackets on fixture housing
#10-32 x 3/8"
Pan head screws
(4x)
1.
Loosely reattach brackets to both sides of fixture housing.
2. Press brackets flush to ceiling tile and secure using #10-32 x
3/8".
ADY071459 REV B (ECN80481)
C-Scroll w/ visor
Ceiling tile
Fixture
assembly
(ceiling grid)
Universal brackets
(2x)
Roundel w/ visor
Wiring the fixture
2.
1. Using cut out dimensions provided on page four(4), cut
hole into dry wall and feed power wire to hole.
2. After removing fixture head, loosen #10-32 x3/8" Pan head
screws and remove cover plate closest to power feed.
3. Knock out appropriate hole for conduit and attach as shown
on page three(3).
4. Replace cover plate and secure with #10-32 x3/8" Pan head
screws and press fixture housing into hole in drywall.
3.
Securing the fixture in drywall
1/4-20 x1 1/2"
Pan head screw
1. Prior to pushing fixture into hole in drywall, tie off fixture
housing to structure using saftey wire(by others) as show on
page three(3).
2. Gently push fixture housing into hole and tighten 1/4-20 x 1
1/2" Pan head screw from inside fixture housing to tighten
drywall bracket around drywall.
3. Connect appropriate wires from fixture head and ensure all
wires are properly matched.
4. Replace fixture head assembly on keyhole screws and
tighten.
Installation Instructions
Small, INDOOR
SRR
(Semi-Recessed, Remote ballast)
Visor and Non-Visor
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
(drywall)
Conduit from
power source.
(by others)
Cover plate
#10-32 x3/8"
Pan head screws
(2x)
Fixture housing
Safety wires
(by others)
(4x)
Sheet 2 of 4
Do not