Operation - Pace SODRTEK ST 600 Operation And Maintenance Manual

Digital paste dispensing system
Table of Contents

Advertisement

Operation

1. Turn the unit "on" by switching the red power button to the on position.
2. Pull the air pressure regulator knob outward and turn clockwise to increase the
air pressure until the desired pressure is indicated.
NOTE: The air pressure output should generally be used between 0.1-2.7bar
(1-40Psi).
3. Set the mode switch to proper position, referring to the adjustment of
dispensing time and interval time.
4. Adjust the dispensing time via the buttons on the front panel. To
adjust, press the "+" button to increase the time and press the "-"
button to decrease the time. There are four digits in all; with the range
from 0.01 second to 99.99 seconds, and the resolution is 0.01 second.
5. Adjust the Interval Time via the buttons on the front panel. To adjust,
press the "+" button to increase the time and press the "-" button to
decrease the time. There are two digits in all; with the range from 0.1
second to 9.9 seconds, and the resolution is 0.1 second.
6. Adjust the vacuum via the Vacuum Control Knob, which is located on the front panel. Turn
clockwise to increase the vacuum and turn the Vacuum Control Knob counterclockwise to
decrease the vacuum.
function is used to prevent the material from oozing after the material
has been dispensed.
NOTE: The barrel material will not drip or ooze unless it has a low
viscosity level. I dripping or oozing does not occur, leave the
Vacuum Control Knob set the fully counterclockwise position.
To high of a vacuum setting could case the material to be
sucked back into the system thus possibly damaging the
station.
7. Insure that the proper material (in barrel) and tip have been installed.
8. Wipe any material residue from the end of tip.
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
The vacuum should be adjusted during the dispensing cycle.