8. Avoid turning barrels upside down or laying barrel, so that material may run through the vacuum
line to the internal components.
9. Do not allow the barrel assemblies to contact hot or sharp objects.
10. Avoid exposing the liquid dispenser to excessive moisture or solvent situations.
NOTE: Dispose of all tips and barrels after use. Always use new tips and barrels to prevent
contamination, insure cleanliness and provide consistent, repeatable material deposition.

Tip Selection

Selection of the proper tip for the application is essential to obtain the optimum deposition rate and
amount. Check the specifications of the material manufacturer for recommended tip sizing. The tip size
and duration of the dispense cycle determine amount of material deposition (dot or bead size). Dispense
several dots (or beads) onto a piece of paper or scrap PC board to check for desired results.

Corrective Maintenance

Most malfunctions are simple and easy to correct.
Symptom
No power to
system
Power, but no
light
Has power and
light but does
not operate
Has power and
light but does
not dispense
Solenoid buzzes
Blowing fuse
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Probable Cause
Blown Fuse
Bad internal connection
No voltage from wall outlet
Power Switch
Bad connection
Reduced or no airflow
Voltage is low
Air is insufficient
Solenoid is not clean
Incorrect rated fuse
Internal short
Solution
Replace fuse.
Unplug from wall, remove top cover, and visually
inspect for any loose or shorted connection.
Check the facility breaker/wiring.
Replace power switch.
Check foot switch (or finger switch) connection.
Unplug from wall, remove top cover and check for
loose connection.
Check air supply and pressure gauge. Reset the
regulator if necessary, remove barrel from
adapter. Depress foot switch (or finger switch) to
check airflow.
Clean or replace solenoid as necessary.
Verify AC receptacle voltage.
Check air supply and pressure gauge.
Clean or replace solenoid as necessary.
Verify the rating of the fuse.
Unplug power input, remove cover, and check
internal wiring for loose connection.
Page 10 of 15