Replacing The Set Point Springs - Samson 44-7 Mounting And Operating Instructions

Excess pressure valve
Table of Contents

Advertisement

8.3 Replacing the set point
springs
DANGER
!
Risk of personal injury due to preloaded
springs.
Regulators in combination with preloaded
set point springs are under tension. These
regulators can be identified by the red warn-
ing label on the actuator's set point springs.
− Before starting any work on the springs,
relieve the compression from the preloaded
springs.
− Only use the SAMSON disassembly tool
(1280-4052).
NOTICE
!
Risk of regulator damage due to exces-
sively high or low tightening torques.
Observe the specified torques when tighten-
ing regulator components. Excessive tighten-
ing torques lead to parts wearing out more
quickly. Parts that are too loose may cause
leakage.
Observe the specified tightening torques.
NOTICE
!
Risk of TÜV approval (based on AGFW
worksheet FW 506) for Type 44-4 becom-
ing void.
Consult SAMSON's After-sales Service be-
fore you change parts or perform service or
repair work on TÜV-tested Type 44-4 Regu-
lators.
EB 2723 EN
Note
SAMSON's After-sales Service can support
you concerning lubricant, tightening torques
and tools approved by SAMSON.
See Fig. 3
Disassembly of Type 44-7
1. Put the regulator out of operation (see
section 10.1).
2. Completely relieve the tension from the
set point spring (8) by turning the set
point adjuster (10) counterclockwise ().
3. Remove the device from the pipeline
4. Unscrew the control line (11).
5. Use the SAMSON disassembly tool to
unscrew the set point adjuster (10) from
the diaphragm stem (7).
6. Lift off the spring plate (9) and the set
point spring (8).
7. Examine the diaphragm stem (7) for
score marks. Replace, if necessary. Pro-
ceed as described in section 8.2.
Assembly of Type 44-7
1. Use the SAMSON disassembly tool to
screw the valve body (1) together with
spring plate (9) and the set point springs
(8).
2. Screw the set point adjuster (10) onto the
diaphragm stem (7).
3. Screw on the control line (11). Observe
tightening torque specified in section 8.4.
4. Put the regulator into operation (see sec-
tion 5.3).