Intrinsically-safe vibration sensor
Table of Contents

Advertisement

CSA
11'
GROUPTM
Models EXRV64xA0y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters
of: Ui (V max)
=
28V, Ii (I max)
=
120mA, Pi = 1W, Ci
=
0, Li
=
121.06 uH; when installed per installation Dwg
30540;
Temp Code T4
@ Max Ambient 80 Deg C.
Models EXRV64xA1y and EXRV64xA6y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with
entity parameters of: Ui (V max)
=
28V, Ii (I max) = 120mA, Pi = 1W, Ci = 61 nF, Li
=
426 H; when installed
per installation Dwg 30540; Temp Code T4
@ Max Ambient 80 Deg C.
Models CS64xB9y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters of:
Ui (V max)
=
30V, Ii (I max)
=
lOOmA, Pi
=
1W, Ci
=
0, Li
=
1.06 uH; when installed per Dwg 56140; Temp
Code T4
@ Max Ambient 80 Deg C.
Notes:
1.
For Canadian Installations, senor case must be bonded to ground according to Section 18-182 of the CEC,
Part 1.
2.
For US Installations, sensor case must be bonded to ground according to Article 501.16 of the NEC.
3.
The "x" in the model code may be a 0 to 9, which denotes variations in frequency response range of the
sensors. The "y" in the model code may be a 0 to 9, which denotes variations in sensor sensitivity.
APPLICABLE REQUIREMENTS
CAN/CSA-C22.2 No. 0-M91
-
General Requirements
-
Canadian Electrical Code, Part IT
C22.2 No. 142-M 1987 (R2009)
-
Process Control Equipment
C22.2 No. 213-M1987 (R2008)
-
Non-Incendive Electrical Equipment for Use in Class I, Division 2
Hazardous Locations
UL 916 (4th Ed.)
-
Energy Management Equipment
UL 1604
(3
31(
Ed.)
-
Electrical Equipment for Use in Class I and II, Division 2; Class III
Hazardous (Classified) Locations
ANSI/ISA 12.12.01-2000
-
Nonincendive Electrical Equipment for Use in Class I and II, Division
2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
CAN/CSA-E60079-15:02
-
Electrical apparatus for explosive gas atmospheres
-
Part 15: Type of Protection "n'
ANSI/UL 60079-15:02
-
Electrical apparatus for Explosive Gas Atmospheres
-
Part 15: Type of
Protection "n"
CLASS 2258 02
-
PROCESS CONTROL EQUIPMENT
-
For Hazardous Locations
CLASS 2258 82 - PROCESS CONTROL EQUIPMENT
-
For Hazardous Locations
-
CERTIFIED TO U.S.
STANDARDS
Ex nA IICT4:
AEx nA TIC T4:
Class I, Div. 2, Groups A, B, C, D:
Models EX64xB7y Vibration Sensors, input rated 28V dc max, 20mA; suitable for use in Class I, Div. 2 or Class
I, Zone 2 locations, when installed per installation Dwg 28766; Temp Code T4
@ Max Ambient 80 Deg C.