1.3 GAS PRESSURE ADJUSTMENT - NATURAL AND PROPANE GAS
Country Appliance Category
A
, I
GB/IE
1
2H
A
, I
GB/IE
1
3P
1.4 HEAT INPUTS - NATURAL AND PROPANE GAS
Country Gas
GB/IE
Natural gas (G20) 6.10kW x6 9.00kW
GB/IE
Propane (G31)
1.5 INJECTOR & BYPASS STAMPINGS - NATURAL AND PROPANE GAS
Country Gas
Natural gas (G20) 193 (type 1)
GB/IE
GB/IE
Propane (G31)
Pressure test point is located towards the centre of gas manifold situated behind front
control facia.
Connect a manometer and check that supply pressure is correct when the oven burner is
ignited and then turned to the highest temperature setting.
1.6 BURNER ADJUSTMENT - NATURAL AND PROPANE GAS
Hotplate and oven burners are fitted with fixed bypass screws and set aeration apertures,
NO ADJUSTMENT is possible.
SECTION 2 - ASSEMBLY AND COMMISSIONING
2.1 ASSEMBLY
Assembly of Ranges
Note: The following paragraphs should be read as applicable to the unit being assembled.
1. If the appliance is supplied with feet: Unpack appliance and place unit in position using
the feet adjusters to level appliance.
2. Open oven door, pull out shelves and loose base panel. Check burner spark igniter
arrangement is correctly located and secured. Ensure ALL packing etc. is removed
from oven. Replace all parts in reverse sequence.
3. Check hotplate, remove packing, etc. from hob area and ensure that all burners
and pan supports are secured in position. The hotplate burner caps fit loosely upon
aluminium skirts of lift-off construction.
2.2 CONNECTION TO GAS SUPPLY
Connect appliance to gas supply. Test for gas tightness.
The integral gas supply downstream of gas valve may be checked by applying leak
detection spray with burner lit. Appliance inlet connection terminates at upper rear RH side
in Rp 3/4 (3/4" BSPP female).
2.3 COMMISSIONING THE APPLIANCE
Important: Prior to operation, ensure ALL packing material has been removed.
2.3.1 Setting the gas pressure
1. It is necessary to check the gas pressure during commissioning and a suitable
pressure gauge must be connected to pressure test point towards the centre of the gas
Gas
Natural gas (G20)
Propane (G31)
Heat Input
(kW net)
Hotplate
Oven
5.40kW x6 9.00kW
Injector Stamping
Hotplate - see spares
page for identification
of hotplates types
200 (type 2)
120 (type 1 & 2)
Inlet Pressure
20mbar
37mbar
Heat Input, Low Setting
(kW net)
Total
Hotplate
45.6kW
0.95kW
41.4kW
0.95kW
Bypass Screw Stamping
Oven Hotplate
240
48 adj. out
155
48 screwed in 72 screwed in
Oven
1.40kW
1.40kW
Oven
72 adj. out

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ce371-p

Table of Contents