Technical Data; General Specification; Control Unit , Cu212-1S - Delta DE212 Installation Manual

Failsafe dp protection including wired deadman timer
Table of Contents

Advertisement

3.
T
D
ECHNICAL
ATA
This equipment is designed for failsafe operation, meeting the stringent requirements for safe operation.
It is in accordance to EU's demands to CE-label the equipment.
3.1
G
S
ENERAL
PECIFICATION
* Temperature Range:
* Shock Resistance:
3.2
C
, CU212-1S
ONTROL UNIT
* Power Supply:
* Power Consumption:
* Outputs:
* Optional inputs
* Connections:
* Indicators:
* Housing:
* Dimensions:
* Weight:
D
RC AS
ELTA
Operational and storage: -25 to +65º C.
2 m free-fall on concrete floor.
11 to 35 VDC. Voltage above 35VDC shuts down the receiver.
Standby: 22 mA.
Semiconductor output. Temperature and overload protected. Output
voltage is equal to power input; 12/24 VDC. Each output, max 3,5A
total load, 5A. Fused inside by 5A slow blow Auto fuse.
* Deadman output. Active when deadman switch is operated.
* Warning light output, active during operation of the deadman
* Beeper warning output
* STOP output. When control unit is powered, this output is active,
output is12/24V. When STOP is detected, this output is switched off, 0V.
*The CU212-1S is programmed to operate with a none failsafe handswitch.
* Deadman override, low input activates the override function
* External STOP, low input actives STOP of deadman function.
Screw terminal on PCB connector.
Green light diode that indicates power on.
Yellow light diode that indicates active deadman.
ABS polycarbonate, class IP52.
L:160 mm, W: 80 mm, D: 60 mm.
0.7 kg
Installation Manual for CU220 DP
Page 8 of 12
Document: 02974

Advertisement

Table of Contents
loading