Inputs/Outputs According To Iso11786:1995; Acoustic Signal Generator; Real-Time Clock; Tab. 15 Input/Output For Ignition - Jetter JetViewMobile 205 User Manual

Isobus terminal
Table of Contents

Advertisement

Jetter AG
Input/output for
ignition
User Manual – JetViewMobile 205

4.10 Inputs/outputs according to ISO11786:1995

Within the operating voltage range, all inputs are voltage-proof and overcurrent
protected.
Parameter
Ignition input/output
Abbreviation
Quantity
Input
Power supply
Output
Max. output current
Tab. 15: Input/output for ignition

4.11 Acoustic signal generator

Category
Type
Volume
Volume control
Frequency range
Tab. 16: Technical data – acoustic signal generator

4.12 Real-time clock

Optional equipment.
Parameter
Description
Battery type
CR2032
Service life
Approx. 10 years from
production.
Tab. 17: Technical data – real-time clock
Description
IGN_KEY
1
12 V
0.5 A
Description
Piezo
> 70 dB
Turned off,
10% ... 100%
200 Hz ... 4 kHz
The service life of the battery
depends on the ambient condi-
tions and may therefore differ.
Technical data | 4
With resonance
frequency and without
mechanical damping.
Controlled via PWM.
16