Ports And Interfaces; Isobus Interface; Usb Interface; Tab. 11: Emitted Radiation Acc. To Cispr 25 - Jetter JetViewMobile 205 User Manual

Isobus terminal
Table of Contents

Advertisement

Jetter AG
Emitted radiation acc.
to CISPR 25
ESD acc. to
EN 61000-4-2
User Manual – JetViewMobile 205
Emitted radiation
Narrowband emission
30 MHz ... 1000 MHz
Wideband emission
30 MHz ... 1000 MHz
Tab. 11: Emitted radiation acc. to CISPR 25
Electrostatic discharge
(ESD)
Contact ±4 kV
Air ±8 kV
Tab. 12: Electrostatic discharge (ESD) acc. to EN 61000-4-2

4.9 Ports and interfaces

4.9.1 ISOBUS interface

Parameter
Baud rate
Protocol
Terminating resistance
Cable specification
Tab. 13: Technical data – ISOBUS interface

4.9.2 USB interface

Parameter
Supply unit
Data rate
Protocol
Tab. 14: Technical data – USB interface
Limit values
30 MHz ... 75 MHz = 52 ... 42 dBµV/m
(logarithmically decreasing)
75 MHz ... 400 MHz = 42 ... 53 dBµV/m
(logarithmically increasing)
400 MHz ... 1000 MHz = 53 dBµV/m (constant)
30 MHz ... 75 MHz = 62 ... 52 dBµV/m
(logarithmically decreasing)
75  MHz ... 400 MHz = 52 ... 63 dBµV/m
(logarithmically increasing)
400  MHz ... 1000 MHz = 63d BµV/m (constant)
Function class
A
A
Description
250 kBaud
ISOBUS
Integrated
CAN-compliant, twisted wire pairs, unshielded
Description
5 V, max. 500 mA
USB 1.1
USB-Host-Interface
Technical data | 4