Ionisation Current; Sensor Values; Coding Plug - Bosch Condens 8300i W Installation And Maintenance Instructions Manual

Wall mounted gas condensing boiler
Table of Contents

Advertisement

Technical information and reports
Max. permissible operating pressure (PMS), heating
Max. permissible operating pressure (PMS), domestic hot water
Permissible ambient temperature short time/long time
Heating water quantity
Weight (without packaging)
Dimensions W × H × D
Maximum installation attitude
Table 30
13.2

Ionisation current

If the burner is running at minimum rated output
Gas type
OK
≥ 7 A
Natural gas
Liquid gas (LPG) ≥ 10 A
Table 31 Ionisation current
13.3

Sensor values

Temperature [°C ± 10 %]
-20
-16
-12
-8
-4
0
4
8
12
16
20
24
Table 32 Outside temperature sensor (for weather-compensated
controllers, accessory)
58
Faulty
< 7 A
< 10 A
Resistance []
2392
2088
1811
1562
1342
1149
984
842
720
616
528
454
GC8300iW 35/40 C
Unit
Natural gas
bar
2.5
bar
10
°C
0 - 50/40
l
5.2
kg
50
mm
440 × 780 ×
365
m
2000
Temperature [°C ± 10 %]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Table 33 Flow temperature sensor
13.4

Coding plug

Type
Gas type
GC8300iW 35/40 C
Natural gas
GC8300iW 35/40 C
Liquid gas (LPG)
Table 34 Coding plug
Propane
Butane
2.5
2.5
10
10
0 - 50/40
0 - 50/40
5.2
5.2
50
440 × 780 ×
440 × 780 ×
365
365
2000
2000
Resistance []
35 975
28 538
22 763
18 284
14 772
12 000
9 786
8 054
6 652
5 523
4 607
3 856
3 243
2 744
2 332
1 990
1 703
1 464
1 261
1 093
949
Number
20456
20457