Slave Compressor Menu
Each of the slaves has a few of their own settings. To check on those, first use the scroll keys to select ECO from
the Menu section. Press Enter key. With the Master option, slave options would be also available depending on the
number of preset slaves. Following screen appears:
Under the slave/compressor (no), there are four menus. First one is "Priority"
schemes. In each Priority scheme a Priority Level can be set per compressor. The lower the priority level the
higher the priority. Compressors with the same Priority Level will have the same Priority. By default all priorities
in both schemes are set to 1. Since two Priority schemes are available, a switch over from one to the other Priority
Scheme is possible (by Digital Input, Week Timer or via Display Menu). Using scroll keys and selecting modify,
the appropriate scheme is chosen.
Section IV - Operating Procedures
Quincy Compressor-QSI
®
. Under priority there are two