Section VII - Compressor Fluids
Understanding the Analysis Report
Reference page 40 for a copy of a blank analysis report.
a) REPORT DATE - The date that the fluid was ana-
lyzed.
b) REPORT NUMBER - The assigned number to this
report.
c) CUSTOMER ADDRESS - The name and address
of person that this report is being mailed to. This
information is being taken from the sample bottle as
it is received.
d) CUSTOMER - The owner of the unit that sample
came from.
e) COMPRESSOR MANUFACTURER - Brand of
compressor sample taken from.
f) FLUID TYPE - This should always be one of the
fluids listed in the previous section.
g) SERIAL NUMBER - The unit serial number of the
Quincy compressor the fluid sample was taken from.
h) MODEL NUMBER - The model number of the
Quincy compressor that the fluid sample was taken
from.
i) HOURS ON FLUID - These are the actual hours
104
that the QuinSyn fluid has been in the unit since the
last fluid change.
j) HOURS ON MACHINE - This is the total hours on
the compressor hourmeter.
k) SAMPLE DATE - The date that the sample was
taken from the compressor.
NOTICE!
Items c) through k) are information provided by
the service person supplying the fluid for analysis.
Incomplete or incorrect information will affect
the report's accuracy.
l) EVALUATION - This is a brief statement made by
the technician performing the actual fluid analysis.
This statement addresses the condition of the fluid
and filter. This statement will also note any prob-
lems that need attention.
m) PHYSICAL PROPERTIES RESULTS - Particle size
is measured in microns. See Fluid Parameters on
pages 42-43.
n) SPECTROCHEMICAL ANALYSIS - See Fluid
Parameters on pages 42-43.