The screen shows the actual unloading and loading pressure settings for both pressure bands.
To modify the settings, move the cursor to the action button Modify and press the Enter key. Following screen appears:
The first line of the screen is highlighted in gray. Use the Scroll keys to highlight the setting to be modified and
press the Enter key. Following screen appears:
The upper and lower limit of the setting is shown in gray, the actual setting is shown in black. Use the ↑ or ↓ key
of the Scroll keys to modify the settings as required and press the Enter key to accept.
If necessary, change the other settings as required in the same way as described above.
38
Regulation
Unloading pressure 1
Loading pressure 1
Unloading pressure 2
Loading pressure 2
Modify
Pressure Band Used
Digital Pressure Band Selection
Power$ync Mode