88. [Dual Screen Off] (Command: s n, 92)
Turn Dual Screen On or Off.
Transmission
(s)(n)( )(Set ID)( )(9)(2)( )(Data)(Cr)
Data
00: MainScreen – On / SubScreen – On
01: MainScreen – Off / SubScreen – On
02: MainScreen – On / SubScreen – Off
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(9)(2)(Data)(x)
* This feature may not be supported in certain models.
89. [Fan control] (Command: d o)
Sets the fan mode.
Transmission
(d)(o)( )(Set ID)( )(Data)(Cr)
Data
00: Auto
01: On
02: Manual
03: Off
Acknowledgement
(o)( )(Set ID)( )(OK/NG)(Data)(x)
* This may not be supported on some models.
90. [Fan Failure Check] (Command: d w)
Checks for fan failures.
Transmission
(d)(w)( )(Set ID)( )(Data)(Cr)
Data
FF: Read status
Acknowledgement
(w)( )(Set ID)( )(OK/NG)(Data1)(Data2)(x)
Data1
00: One or more fans are faulty.
01: All fans are normal.
02: The model has no fan.
Data2
00: No fan is faulty (all fans are normal).
01: 1 fan is faulty.
02: 2 fans are faulty.
03: 3 fans are faulty.
04: 4 fans are faulty.
05: 5 fans are faulty.
06: 6 fans are faulty.
07: 7 fans are faulty.
08: 8 fans are faulty.
09: 9 fans are faulty.
0A: 10 fans are faulty.
...
N: N down
91. [Luminance Value Read] (Command: m u)
Reads luminance value.
Transmission
(m)(u)( )(Set ID)( )(FF)(Cr)
Acknowledgement
(u)()(SetID)()(OK/NG)(Data1)(Data2)(Data3)
(Data4)(Data5)(Data6)(Data7)(x)
Data1
00–64: The Backlight PWM value (0 to 100)
Data2
00–ff: The upper 1-byte of the value measured by the
CA210.
Data3
00–ff: The lower 1-byte of the value measured by the
CA210.
CA210 measurement:
0000
in decimal.
Data4
00–ff: The upper 1-byte of the value measured by BLU 1
sensor.
Data5
00–ff: The lower 1-byte of the value measured by BLU 1
sensor.
Data6
00–ff: The upper 1-byte of the value measured by BLU 2
sensor.
Data7
00–ff: The lower 1-byte of the value measured by BLU 2
sensor.
BLU measurement:
0000
to ffff in hexadecimal and 0 to
in decimal.
* During final assembly, a CA210 measurement is entered through the
calibration procedure. The default value, before calibration, is 0.
* This may not be supported on some models.
92. [BLU Maintenance] (Command: m t)
Selects whether to turn on/off BLU Maintenance.
Transmission
(m)(t)( )(Set ID)( )(Data)(Cr)
Data
00: BLU Maintenance Off
01: BLU Maintenance On
Acknowledgement
(t)( )(Set ID)( )(OK/NG)(Data)(x)
* This may not be supported on some models.