Fujitsu ARHG24LMLA Design & Technical Manual page 32

Table of Contents

Advertisement

¢ Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE: Setting will not be changed if invalid numbers or setting values are selected.
 Function setting list
Function no.
1)
11
2)
21
3)
30
4)
31
5)
40
6)
42
7)
43
8)
46
9)
48
10)
49
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the esti-
mated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
11
2) Static pressure
Select the appropriate static pressure according to the installation conditions.
Function number
21
3) Room temperature sensor control for cooling
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
Function number
30
Filter sign
Static pressure
Room temperature sensor control for cooling
Room temperature sensor control for heating
Auto restart
Room temperature sensor switching
Cold air prevention
External input control
Room temperature sensor switching (Aux.)
Indoor unit fan control for energy saving for cooling
Setting value
00
01
02
03
Setting value
00
01
02
03
Setting value
00
01
02
03
- 28 -
Functions
Setting description
Standard (2,500 hours)
Long interval (4,400 hours)
Short interval (1,250 hours)
No indication
Setting description
Normal
High static pressure 1
High static pressure 2
High static pressure 3
Setting description
Standard
Slightly lower control
Lower control
Higher control
Factory setting
Factory setting
Factory setting