Description
Further
15 kW rectifier unit:
connections:
♦ C' / D'
♦ "Fault" relay output
♦ "Pulse disable" relay output
50 kW / 100 kW rectifier units
♦ "Fault" relay output
2-2
Voltage output for the pre-charging of optionally connected capacitor
modules for supporting the DC link and for storing regenerative
energy
6SE7024-1EP85-0AA0
In case of a fault the main
contactor must be de-energized
via this contact and the inverters
disabled.
6SE7024-1EP85-0AA0
Does not exist
In case of a fault the main contactor has to be de-energized via this
contact and the inverters disabled.
Operating Instructions
05.2005
6SE7024-1EP85-0AA1
In case of a fault the main
contactor must be de-energized
via this contact.
6SE7024-1EP85-0AA1
During pre-charging or in case
of a fault the inverters must be
disabled via this contact.
6SE7087-2NP85-0AA0