Whitney Even on 06/22/2022
The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a
red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM
DOCUMENTS "
with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid
width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will
accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the
enclosure. A legend sheet will be permanently attached to the door for system required documentation, key
contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital
flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall
not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide
2 key ring holders with a location to mount standard business type cards for key contact personnel.
Space Age Electronics, Inc.
www.1sae.com
800.486.1723 Toll Free
508.485.0966 Local
508.485.4740 Fax
USB Storage Interface
Requires Standard USB-B
Connector
Key Ring
Hooks
Business
Card Holder

Ordering Information:

Part #
Description
SSU00685 Fire Alarm Storage Cabinet RED
SSU00686 Custom screening with your Logo
solutions (IAMEFAD)
This document is subject to change without notice, see doc # ED0479 for legal disclaimer
ED0549
For replacement forms order P/N: EA0316 (Qty. 10)
Property Information
Minimum Required Documentation (SIG-FUN)
(Reference NFPA-72 2013 Section 7.2.1)
Name of property: ________________________
1 Written narrative providing intent and system description
Address: ________________________________
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Description of property:_____________________
Occupancy type:__________________________
2 Riser diagram
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Certifications and Approvals
3 Floor plan layout showing location of all devices and control equipment
16.1 System Installation Contractor:
□ N/A □ Enclosed Or Alt. Location _____________________________________________
This system, as specified herein, has been installed and
tested according to all NFPA standards cited herein.
4 Sequence of operation in either an input/ output matrix or narrative form
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Signed:_______________________
Printed name:__________________
5 Equipment technical data sheets
Date: ____ / ____ / ____
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Organization:__________________
Title:_________________________
6 Manufacturers published instructions, including operation and maintenance instruction
Phone: _______________________
□ N/A □ Enclosed Or Alt. Location _____________________________________________
7 Battery calculations (where batteries are provided)
16.5 Authority Having Jurisdiction:
□ N/A □ Enclosed Or Alt. Location _____________________________________________
I have witnessed a satisfactory acceptance test of this
system and find it to be installed and operating properly
8 Voltage drop calculations for notification appliance circuits
in accordance with its approved plans and specifications,
□ N/A □ Enclosed Or Alt. Location _____________________________________________
with its approved sequence of operations, and with all
NFPA standards cited herein.
9 Completed record of inspection and testing in accordance with 7.6.6 and 7.8.2
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Signed:_______________________
Printed name:__________________
10 Completed record of completion in accordance with 7.5.6 and 7.8.2
Date: ____ / ____ / ____
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Organization:__________________
Title:_________________________
11 Copy of site specific software, where applicable
Phone: _______________________
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Equipment Information
12 Record (as-built) drawings
□ N/A □ Enclosed Or Alt. Location _____________________________________________
ID No 1: ________________________
13 Periodic inspection, testing, and maintenance documentation in accordance with Section 7.6
Serial: __________________________
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Access code:_____________________
14 Records, record retention, and record maintenance in accordance with 7.7
ID No 2: ________________________
□ N/A □ Enclosed Or Alt. Location _____________________________________________
Serial: __________________________
Access code:_____________________
Space Age Electronics, Inc.
58 Chocksett Road
Sterling, MA 01564
Legend sheet for storing system information
including contacts, sign-o , maintenance &
test information, and alternate locations
of additional records.
Space Age Electronics, Inc.
LT10559
Rev.D
Signed:_______________________ Date: ____ / ____ / ____