Technical Data - Graco E-Flo Plus Installation Manual

Electric circulation pump
Hide thumbs Also See for E-Flo Plus:
Table of Contents

Advertisement

Technical Data

Maximum Working Pressure . . . . . . . . . . . . . . . . . . . . . . 1000 cc Pumps: 460 psi (3.22 MPa, 32.2 bar)
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . European Models: 230/400 Vac, 3 phase, 20 A
Ambient Temperature Range . . . . . . . . . . . . . . . . . . . . . . 32-104°F (0-40°C)
Maximum Fluid Output (at 20 cpm) . . . . . . . . . . . . . . . . . 22.6 gpm (85.6 liters per min) with 2000 cc lowers. See
Fluid Inlet and Outlet Size . . . . . . . . . . . . . . . . . . . . . . . . 2 in. Tri-clamp
Gear Reducer Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . 2 quarts (1.9 liters)
Required Gear Reducer Lubricant . . . . . . . . . . . . . . . . . . ISO VG220 grade oil (Graco Part No. 288414)
Weight (with motor and 2000 cc lowers) . . . . . . . . . . . . . Pump: 550 lb (249 kg)
Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lower: see manual 311690
Maximum Production Motor Speed . . . . . . . . . . . . . . . . . 1500 rpm (50 Hz)
Maximum Motor Torque . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ft-lb (20.3 N•m)
Gear Reduction Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75.16:1
psi (MPa, bar)
500 (3.50, 35.0)
450 (3.15, 31.5)
400 (2.80, 28.0)
350 (2.41, 24.1)
300 (2.10, 21.0)
250 (1.72, 17.2)
200 (1.4, 14.0)
150 (1.03, 10.3)
100 (0.70, 7.0)
50 (0.35, 3.5)
311592B
Pressure and Flow Capability of E-Flo Plus
(continuous production use)
A
0
5
(38)
(19)
Fluid Flow in gpm (lpm)
1500 cc Pumps: 330 psi (2.31 MPa, 23.1 bar)
2000 cc Pumps: 250 psi (1.75 MPa, 17.5 bar)
North American Models: 230/460 Vac, 3 phase, 15 A
chart below.
300 Series SST, CV-75, 17-4 PH SST, PTFE
B
15
20
10
(76)
(57)
Key:
A
1000 cc Pumps
B
1500 cc Pumps
C
2000 cc Pumps
C
25
(95)
Technical Data
19

Advertisement

Table of Contents
loading

Table of Contents