1. Getting to know your device on the packaging and on the type plate for the device and the Check that the packaging of the Sanitas MD4200 blood pres- accessories: sure monitor has not been tampered with and make sure that Attention the required contents are present.
Page 3
any medical decisions on them (e.g. medicines and their Permissible storage temperature and humi - Stor age administration). 70°C dity • Do not use the blood pressure monitor on newborns or pati- -25°C RH ≤93% ents with preeclampsia. We recommend consulting a doctor Permissible operating temperature and Oper ating before using the blood pressure monitor during pregnancy.
Page 4
• Do not place the cuff over wounds as this may cause further Notes on handling batteries injury. • If your skin or eyes come into contact with battery °uid, rinse • Please note that data transfer and data storage is only pos- the affected areas with water and seek medical assistance.
3. Device description Instructions for repairs and disposal • Batteries do not belong in household waste. Please dispose of empty batteries at the collection points intended for this purpose. • Do not repair or adjust the device yourself. Proper operation can no longer be guaranteed in this case.
Information on the display: System requirements for the HealthCoach app Bluetooth 4.0, iOS from Version 7.0, Android devices from ® Version 4.3 with Bluetooth Smar t Ready ® List of co mpatible devices: 4. Preparing the measurement Inserting the batteries •...
Page 7
Set the hour format, date, time and Bluetooth ® settings The year °ashes on the display. The following section describes the functions and settings • Select the year using the M1/M2 memo- available on the blood pressure monitor. ry buttons and conÿrm with the START/ STOP button ®...
Now insert the cu˛ line into the The Bluetooth symbol flashes on the display . ® connection for the cu˛ connect o r. • Use the M1/M2 memory buttons to select whether automatic Bluetooth data transfer is activated ( Blue- ®...
Page 9
Adopting the correct posture Performing the blood pressure measurement As described above, attach the cuff and adopt the po- sture in which you want to perform the measurement. • Press the START/STOP button to start the blood pressure monitor. All display elements are brie°y displayed. •...
Page 10
• Now select the desired user memory by pressing the Please note that you must add the blood pressur e M1 or M2 memory buttons. If you do not select a user monitor in "My devices" in the "HealthCoach" app to memory, the measur e ment is stored in the most re enable data transfers.
Page 11
Arrhythmia can only be determined through an examination by Blood pressure Systole Diastole Action your doctor. (in mmHg) (in mmHg) value category If the symbol is shown on the display after the measur e Setting 3: seek medical at - ment has been taken, repeat the measur e ment.
7. Display and delete measured values Press the M1 button if you have select e d user memory 1. The results of every successful measur e ment are stored Press the M2 memory button if you have together with the date and time. The oldest measur e ment is overwritten in the event of more than 60 measur e ments.
Page 13
When the relevant memory button ( M1 or To clear individual measur e ments from the relevant user M2 ) is pressed again, the last individual memory, you must first select a user memory. measur e ment is displayed (in this example, •...
Step 2: "HealthCoach" app • Clean the device and cu˛ carefully using a slightly damp cloth only. In the HealthCoach app, add the MD4200 under • Do not use any cleaning agents or solvents. "Settings/My devices". • Under no circumstances should you hold the unit under wa- ter, as this can cause liquid to enter and damage the unit.
Battery life depending on the blood pressure and inflation pressure as well as the number 10. Technical specifications of Bluetooth® connections. Model No. MD4200 Accessories Cuff˛, instructions for use, storage Measur e ment me - Oscillometric, non-invasive blood pouch thod...
Page 16
• The accuracy of this blood pressure monitor has been care- Technical information is subject to change without notification to allow for updates. fully checked and developed with regard to a long useful life. This device complies with European Standard EN60601-2 and If using the device for commercial medical purposes, it must be regularly tested for accuracy by appropriate means.
Page 17
• Warning:Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Digital Automatic Blood Pressure Monitor (model name: MD4200), including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
Page 18
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 19
Guidance and manufacturer’s declaration - electromagnetic emissions The Sphygmomanometer (MD4200) is intended for use in the electromagnetic environment specified below. The customer or the user of the Sphygmomanometer (MD4200) should assure that it is used in such an environment. Emissions test...
Page 20
Guidance and manufacturer’s declaration - electromagnetic Immunity The Sphygmomanometer (MD4200) is intended for use in the electromagnetic environment specified below. The customer or the user of the Sphygmomanometer(MD4200) should assure that it is used in such an environment. Compliance level...
Guidance and manufacturer’s declaration - electromagnetic Immunity The Sphygmomanometer (MD4200) is intended for use in the electromagnetic environment specified below. The customer or the user of the Sphygmomanometer (MD4200) should assure that it is used in such an environment. Test Frequency...
Page 22
Guidance and manufacturer’s declaration - electromagnetic Immunity The Sphygmomanometer (MD4200) is intended for use in the electromagnetic environment specified below. The customer or the user of the Sphygmomanometer (MD4200) should assure that it is used in such an environment. Test frequency...
Page 23
Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. No.