2-6-3 Operation

1) Normal Operation
The status of the emitter / receiver indicators during normal operation is as described below.
Device status
Light received status
(all beams received)
One or more lights
block
Notes: 1) Since the color of the operation indicator changes according to the ON / OFF state of the control output
(OSSD 1 / 2), the operation indicator is marked as OSSD on the device.
2) The status of the emitter / receiver indicators during operation above shows the case in PNP output
setting mode. In case of NPN output setting mode, the NPN indicator (orange) lights up.
© Panasonic Industriar Devices SUNX Co., Ltd. 2014
: Blinks
in red
Emitter
Beam-axis alignment
indicator (Green)
Operation indicator
(Green) (Note 1)
Incident light intensity indicator
(Green)
Fault indicator
Digital error indicator
PNP indicator (Orange) (Note 2)
NPN indicator
Emission intensity control indicator
Emission halt indicator
Beam-axis alignment
indicator (Red)
Operation indicator
(Red) (Note 1)
Incident light intensity indicator
Fault indicator
Digital error indicator
PNP indicator (Orange) (Note 2)
NPN indicator
Emission intensity control indicator
Emission halt indicator
: Lights up
: Lights up
in red
in green
Indicators
Receiver
Beam-axis alignment
indicator (Green)
OSSD indicator (Green)
Incident light intensity indicator
(Green)
Fault indicator
Digital error indicator
PNP indicator (Orange) (Note 2)
NPN indicator
Function setting indicator
Interlock indicator
Beam-axis alignment
indicator (Red)
OSSD Indicator (Red)
Incident light intensity indicator
Fault indicator
Digital error indicator
PNP indicator (Orange) (Note 2)
NPN indicator
Function setting indicator
Interlock indicator
: Lights up
: Turns
in orange
OFF
Control output
OSSD 1
OSSD 2
ON
OFF
61