7.5.4 Paper Empty Sensor (PE) / OHP Sensor (OHP)

Tools
1
. Phillips Screwdriver #1
Disassembly Procedures
1
. Remove the transfer unit. (See the item 7.6.1.)
2
. Remove the set screw ST3 6 (2 pcs.) of paper guide (L).
3
. Remove the paper guide (L).
4
. Remove the set screw ST3 6 (2 pcs.) of paper guide assembly (UL).
5
. Remove the connector connected with the sensor.
6
. Remove the paper guide assembly (UL).
7
. Remove the paper empty sensor (PE) from the paper guide assembly (UL), or
remove the set screw BT3 8 (2 pc.) of OHP sensor (OHP) from the paper guide
assembly (UL).
8
. Remove the OHP sensor (OHP).
Assembly Procedures
1
. Install a new paper empty sensor (PE) or a new OHP sensor (OHP) to the paper
guide assembly (UL).
2
. After the above , follow exactly the reverse order of disassembling procedures.
Precautions