Download Print this page

Commissioning / Use - Vauconsant EXIGENCE A62408 User Manual

Pulsed air bain-marie with free space below and heating display option

Advertisement

Controls:
The controls are placed on a removable panel to the right of the unit.
A mechanical thermostat with orange on-off light for the bain-marie well.
o
A switch with orange light for the heating display option.
o
Commissioning:
Preheating of the well one hour before use.
The heating display should be switched on at the start of service.
Use:
Bain-marie well
Turn the thermostat button to the right, set it to the maximum position. This position maintains the
temperature of food above °63°C which is the minimum temperature defined by the hygiene
department.
This temperature is maintained for 120 minutes, using GN1/1 gastronorme trays, 150 deep.
To maintain this temperature, it is necessary to bring food at a temperature between
+70 and +80°C. Each gastronorme tray should also be fitted with a lid.
The temperature of the well may be set from 30°C to 110 °C.
Heating display (option)
Press the switch:
position 0 = Off
position 1 = On.
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/ 2010

Commissioning / Use

USER MANUAL
- 6 -

Advertisement