Lincoln Electric MOBIFLEX 200-M/HE Instruction Manual page 15

Mobile filter unit & lfa 3.1 / 4.1 extraction arm
Table of Contents

Advertisement

A-8
FIGURE A.13
A
If the entire arm falls on its own:
(See Figure A.13, items A and B)
• Tighten bolt (A) on the hinge fan side to increase
spring tension. Ensure spring does not turn as you
tighten. See Figure A.14.
If the hood section of the arm falls on its own:
(See Figure A.13, item B)
FIGURE A.14
A
• Tighten bolt (A) in middle hinge to increase spring
(B) tension. Ensure spring does not turn as you tight-
en. See Figure A.15.
FIGURE A.15
MOBIFLEX 200-M(/HE) MOBILE FILTER UNIT & LFA 3.1 / 4.1 EXTRACTION UNIT
INSTALLATION
LFA 3.1/4.1 MOBILE
MANUAL/AUTOMATIC
A hose running guard is attached to the middle hinge
B
of the extraction arm by a piece of tape.
See Figure A.16
1. Take the hose running guard (A) and snap it into
2. Fold back 2/3 of both rubber seals.
3. Remove the wrap of the flexible hose.
4. Place the flexible hose over both arm sections. To
5. Fold back the rubber seals and place them over the
Now mount the flexible hose at the hood side.
6. Fold back 2/3 of both rubber seals.
7. Remove the wrap of the flexible hose hood side.
8. Place the flexible hose over the hood and the arm
9. Fold back the rubber seals and place them over the
A
B
place at the middle hinge (B).
secure the hose, at least one metal rings of the
hose should be applied over the ridges at each arm
section.
hose. The rubber seal should cover the arm section
0.5-1 in.
FIGURE A.16
A
section hood side. To secure the hose, at least one
metal rings of the hose should be applied over the
ridges.
hose. The rubber seals should cover the hood and
the arm section 0.5-1 in.
A-8
B

Advertisement