IEC CL40 - FL40 Series
User's Manual
TM
Analyze
Detect
Measure
Control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IEC CL40 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo Electron IEC CL40 Series

  • Page 1 IEC CL40 - FL40 Series User’s Manual Analyze Detect Measure Control • • •...
  • Page 2 IEC CL40 - FL40 Series User’s Manual CL40 - FL40 Series...
  • Page 3 Carefully read this manual before operating your instrument. Information contained in this document is the property of Thermo Electron Corporation; it may not be duplicated or distribuited without the owner’s authorization. The validity of the guarantee is subject to the observation of the instructions...
  • Page 4 Preface MANUAL NUMBER ECR/ECN DATE DESCRIPTION 11290088 03/06 Initial release Thermo Electron Corporation CL40 - FL40...
  • Page 5 Mains cord 26227005 Toolbox: 26339005 • Rotor removal tool 85241084 • Emergency unlooking tool 86000897 • 12 and 13 mm wrench 25055501 • 21 mm wrench For missing parts call your nearest Thermo representative CL40 - FL40 Thermo Electron Corporation...
  • Page 6 Europea 2002/96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici (WEEE). È marcato col seguente simbolo. Thermo Electron ha stipulato contratti con una o diverse società di riciclaggio/smaltimento in ognuno degli Stati Membri Europei. Questo prodotto verrà smaltito o riciclato tramite queste medesime. Ulteriori informazioni sulla conformità...
  • Page 7 WEEE Compliance de los productos de Thermo Electron que puedes asistir en la deteccion de substancian mensionades en la directiva RoHS, explicado en www.thermo.com/WEEERoHS France Conformité WEEE. Ce produit doit être conforme à la directive euro- péenne (2002/96EC) des Déchets d’Equipements Electriques et Electroniques (DEEE).
  • Page 8 CHATEAU-GONTIER, France, déclarons que le matériel désigné ci- après est conforme aux directives européennes suivantes: Konformitätserklärung Wir, Thermo Electron Industries S.A.S. , Z.I. d'Aze Bellitourne 53200, CHATEAU-GONTIER, France, erklären dass das hier beschriebene Gerät sich in Übereinstimmung mit folgenden europäischen Richtlinien befindet: Declaración de conformidad...
  • Page 9 ONE YEAR from the delivery. This guarantee is invalid if the unit is incorrectly used, poorly serviced or neglected, mis-used or accidentally damaged. There is no explicit guarantee other than as stated above. CL40 - FL40 Thermo Electron Corporation...
  • Page 10 Tel.: +32 24 82 30 30 Visit our web site at: www.thermo.com Germany Tel.: +49 61 84 90 69 40 Fax: +49 61 03 40 81 012 Finland Tel.: +35 89 32 91 00 Thermo Electron Corporation CL40 - FL40...
  • Page 11: Table Of Contents

    Display Screens ................4-2 Control Panel Functions ..............4-3 Control Panel Indicators ..............4-4 Description of Certain Events with Respect to the Control System ..4-5 Preparing the First Run of the Day ..........4-7 Sample Loading ................4-7 viii CL40 - FL40 Thermo Electron Corporation...
  • Page 12 Service and Maintenance ................6-1 Periodic Cleaning ................6-1 Contamination Hazards ..............6-1 Disinfection ..................6-2 Radioactive Decontamination ............6-2 Power Supply Circuit Breaker............6-3 Rotor Removal ..................6-3 Trunnion Lubrication................6-3 Chemical Compatibility Table for Rotors, Tubes and Accessories..6-4 Chapter 7 Disposal of Product..................7-1 Thermo Electron Corporation CL40 - FL40...
  • Page 15: Use And Function

    Centrifugal force provided by the centrifuge can also be used to drive solvents and low molecular weight solutes through the membrane of a filtering device. Retained macrosolutes will therefore be found above the membrane. Relative Centrifugal Force (RCF) generated by a rotor is directly Thermo Electron Corporation CL40 - FL40...
  • Page 16: Refrigeration And Heating Systems

    Near the drain hose you can find the following label: To remove condensation, please follow this procedure: • Switch off the centrifuge and disconnect the power. • Put a small basin under the hose. • Unplug the hose. CL40 - FL40 Thermo Electron Corporation...
  • Page 17: Drive System

    As soon as the motor stops, open the centrifuge and redistribute the samples to produce an equal weight on diametrically opposite sides. If the message persists, despite your efforts to balance the load, call your Thermo Service representative. Thermo Electron Corporation CL40 - FL40...
  • Page 18: Relative Centrifugal Force

    Note : The value introduced for the radius can be adjusted to allow for position within the tube such as at a boundary. Maximum radii are quoted in the specifications tables. Use of improper radius will adjust the speed setting, automatically applying the wrong RCF. CL40 - FL40 Thermo Electron Corporation...
  • Page 19: Chapter 2 Specifications

    10 rpm at less than 1000 rpm 10 rpm at less than 1000 rpm 100 rpm at above 1000 rpm 100 rpm at above 1000 rpm Accuracy ± 20 rpm (display) ± 20 rpm (display) Thermo Electron Corporation CL40 - FL40...
  • Page 20: Electrical Specifications

    Nominal operating voltage 230V 230 V ±10% 230 V ±10% 120V 120 V ±10% 120 V ±10% Power requirements (maximum) 1200 W 1500 W Heat output (maximum) 3750 BTU / h 4435 BTU / h CL40 - FL40 Thermo Electron Corporation...
  • Page 21: Chapter 3 Installation

    • Check the contents of the package using the packing list provided above. • Keep the packaging until the centrifuge has been tested and found fully functional. Thermo Electron Corporation CL40 - FL40...
  • Page 22: Positioning

    A supply fitted with a circuit breaker of the correct rating complies with this requirement. CL40 - FL40 Thermo Electron Corporation...
  • Page 23: Lid Opening And Rotor Checking

    Rotating parts are a risk as they could come in contact with the user or be ejected. There is particularly high risk of injury if: • The user attempts to manually stop the rotor Thermo Electron Corporation CL40 - FL40...
  • Page 24 If it is necessary to open the lid manually, wait 10 min. or until the rotor has stopped rotating, before using the lid opening tool provided. This label must be changed once it has been pierced. CL40 - FL40 Thermo Electron Corporation...
  • Page 25: Performance And Accessories

    Lid - for 600 ml bottle Cytology accessories (for use with the insert 11174202): 11172499 Cytobuckets (2) 11203558 Cytobucket slides (50) 11203559 Cytobucket foam layers (50) 11203561 Tube of silicone 11203562 Blotting paper pad Thermo Electron Corporation CL40 - FL40...
  • Page 26 11174202 Black Cytoblock 180 4000 3220 4500 4075 11174203 600 flat 4000 3399 4500 4302 See Corning for adapters 500 con 4000 3399 4500 4302 81005750 Bottle (set of 6) 4000 3184 4500 4098 CL40 - FL40 Thermo Electron Corporation...
  • Page 27 Max Tube Max* Tube (set of 4) or type Capacity Capacity Ø [mm] tube height volume Radius Speed Speed [mm] [mL] [mm] [rpm] [x g] [rpm] [x g] 11175371 250 con 4000 3721 4500 4709 Thermo Electron Corporation CL40 - FL40...
  • Page 28: Biocontainement Accessories

    • 8000 rpm / 9588 x g • 35° angle • round bottom Cat. No. Insert capacity Max tube Ø (mm) Accessory description 64662300 16.5 Set of 8 adaptors for 10 mL vac tubes CL40 - FL40 Thermo Electron Corporation...
  • Page 29 Set of 10 adaptors for 15 mL conical CD 3 angle rotor • 40x15mL tubes Ø 18.5 mm • L min/max 93/110mm • 8000 rpm / 10375 x g • 35° angle • round bottom Thermo Electron Corporation CL40 - FL40...
  • Page 30: Glassware

    95 ml Glass round 41191262 11174166 104 ml Glass round 41191160 11174166 130 ml round 41193164 11174166 375 ml Glass round 41191186 11174192 485 ml round 41193189 11174192 PP: Polypropylene O: Open C: Capped 3-10 CL40 - FL40 Thermo Electron Corporation...
  • Page 31: Instructions For Use

    Imbalance Indicator Temperature set (CL40R, FL40R) Lid Opening allowed Indicator Speed Indicator Display Screens RCF Indicator Upper Screen: speed/RCF Time Indicator Middle Screen: time/raduis Radius Input Indicator Lower Screen: accel./decel. rates/temp. (R mod.) (CL40R, FL40R) Thermo Electron Corporation CL40 - FL40...
  • Page 32: Display Screens

    In addition, it shows the temperature in the bowl of the centrifuge. When the centrifuge is at rest, the set bowl temperature is displayed (°C). During a run, the actual bowl temperature is displayed (°C). CL40 - FL40 Thermo Electron Corporation...
  • Page 33: Control Panel Functions

    To unlock a program (when a program is locked, the associated LED flashes), press and hold the corresponding button for several seconds until the associated LED stops flashing. Release the but- ton, and the program is unlocked. Thermo Electron Corporation CL40 - FL40...
  • Page 34: Control Panel Indicators

    The rotor will be decelerated to rest, at which time the lid can be opened and the load can be re-balanced. When the lid is opened this indicator will go off. CL40 - FL40 Thermo Electron Corporation...
  • Page 35: Description Of Certain Events With Respect To The Control System

    ‘beep’ and the middle display will show the word ‘End’. Pressing any button or opening the lid will bring the displays back to their normal ‘at rest’ configuration (display of set parameters). Thermo Electron Corporation CL40 - FL40...
  • Page 36 If the centrifuge is operated in Overtemperature good conditions and the (Bad operating problem remains, please conditions or contact THERMO service cooling unit failure). Electronic All controls disabled. Reset the device by powering malfunction. it down. CL40 - FL40 Thermo Electron Corporation...
  • Page 37: Preparing The First Run Of The Day

    180 degrees from the rotation axis and at equal distance (radius) from the center of rotation (see pictures). When using fixed angle rotor, weight deviation between the tubes must not exceed ±5 grams. Thermo Electron Corporation CL40 - FL40...
  • Page 38 An odd number of tubes requires an additional blank, water-filled tube of identical total weight to balance. Significant vibrations can damage the accessories, the unit and the samples. Most vibration is caused by incorrect loading of the tubes. For CL40 - FL40 Thermo Electron Corporation...
  • Page 39 See chapter 6.6 for details. If the message persists, despite your efforts to balance the load, call your Thermo Service representative. Thermo Electron Corporation CL40 - FL40...
  • Page 40: Iec 1010-2-020

    Use only rotors and accessories designed for use in these centrifuges. ▲ Pay special attention to the following: • Installation of the unit: proper ventilation, leveling of the centrifuge, rigidity and stability of the support. CL40 - FL40 Thermo Electron Corporation...
  • Page 41: Speed Control

    Thus the risk of the spread of aerosols is significant in a ventilated centrifuge. In the case of samples presenting a biological or chemical risk, the operator must take suitable precautions to prevent or reduce this risk. Thermo Electron Corporation CL40 - FL40...
  • Page 42 When an elevated risk of aerosols or of breakage is perceived the accessories should be handled using gloves and opened in an environment ensuring the protection of the operator (safety cabinet, glove chamber, wearing a mask ...), even if they are apparently sealed. ▲ CL40 - FL40 Thermo Electron Corporation...
  • Page 43: Service And Maintenance

    If decontamination procedures require the use of warming (i.e. autoclave) the rotating equipment should always be completely disassembled before being subjected to heat and after external chemical cleaning. Seals should be decontaminated with the method most suitable for them. Thermo Electron Corporation CL40 - FL40...
  • Page 44: Disinfection

    Rotors may be decontaminated by a mixture of equal volumes of: • Distilled water, • SDS diluted to 10%, • Ethanol diluted to 70%. The rotor should then be rinsed with ethanol followed by distilled water and then dried completely. CL40 - FL40 Thermo Electron Corporation...
  • Page 45: Power Supply Circuit Breaker

    If the centrifuge is having imbalance problems, try this operation before calling Thermo service. In many cases, imbalance problems arise due to the fact that poorly maintained bucket-trunnion interfaces prevent the buckets from swinging freely. ▲ Thermo Electron Corporation CL40 - FL40...
  • Page 46: Chemical Compatibility Table For Rotors, Tubes And Accessories

    Ammonium Carbonate Ammonium Chloride St St Ammonium Hydroxide (10%) Ammonium Hydroxide (conc) Ammonium Oxalate O Sd Ammonium Phosphate Ammonium Sulphate Ammonium Sulphide n-Amyl Acetate O Sd U Sd Sd Amyl Alcohol Amyl Chloride Aniline CL40 - FL40 Thermo Electron Corporation...
  • Page 47 Chlorine, moist O Mt Sd St Mt O Chloroacetic Acid O Sd Mt S p-Chloroacetophenone Chlorobenzene Chloroform Chlorosulphonic Chromic Acid (5 %) Chromic Acid (10%) Chromic Acid (50%) Cinnamon Essence Citric Acid (10%) Copper Nitrate Thermo Electron Corporation CL40 - FL40...
  • Page 48 Ethyl Lactate Ethyl Malonate S Mt S Fatty Acids O Sd Sd Sd Sd Ferric Chloride Ferric Nitrate Ferric Sulphate Ficoll Paque Fluorine O Mt Sd St Mt U Fluorhydric Acid (10%) Fluorhydric Acid (50%) CL40 - FL40 Thermo Electron Corporation...
  • Page 49 Methanol (100%) Methyl Acetate Methyl Alcohol (100%) Methyl Butyl Ketone Methyl Ethyl Ketone Methyl Isobutyl Ketone Methyl Isopropyl Ketone Methylene Chloride Mineral Oil O Mt U Mt Mt Mt O Nickel Chloride Nickel Salts Thermo Electron Corporation CL40 - FL40...
  • Page 50 Potassium Chloride Potassium Hydroxide (5%) Potassium Hydroxide (conc.) Potassium Nitrate Potassium Permanganate Propane Gas Propionic Acid O Sd M Sd Propyl Alcohol Propylene Glycol Sd S Propylene Oxide Pyridine Resorcinol, Sat’d., Sol Sd S CL40 - FL40 Thermo Electron Corporation...
  • Page 51 1,2,4 - Trichlorobenzen Trichloroethane Triethylamine Triethylene Glycol Sd S Tris Buffer (neutral) Trisodium Phosphate Triton X-100 Turpentine O Sd Mt St Sd Undecyl Alcohol O Sd Sd St Sd M Urea Urine Vinylidene chloride Thermo Electron Corporation CL40 - FL40...
  • Page 52 * This table is intended as a guide only because of the difficulty in quantifying, cross-checking and monitoring the results under different conditions of temperature, pressure and purity relating to the solvents and samples dissolved therein. It is strongly recommended that you carry out your own trials, particularly before protracted work periods. 6-10 CL40 - FL40 Thermo Electron Corporation...
  • Page 53: Disposal Of Product

    Disposal of these elements must be in accordance with applicable regulations and recommendations defined by the relevant regulatory bodies. In additions, these elements must be disposed of differently based on the different noxious substances they contain (possibly by a specialized disposal company). Thermo Electron Corporation CL40 - FL40...
  • Page 54 • Clean the instrument and proceed to its decontamination from any kind of dangerous products. • Compile this Decontamination Certificate with all the information required. CL40 - FL40 Thermo Electron Corporation...
  • Page 55 Customer Service representative. In the event these certificates are not available, a written statement certifying that the instrument or part has been properly decontaminated and outlining the procedures used will be acceptable. For your convenience, use a copy of this page Thermo Electron Corporation CL40 - FL40...
  • Page 56 11290088a...