Do you have a question about the HAAKE Phoenix II P1 and is the answer not in the manual?
Questions and answers
Missy Hasbargen
April 29, 2025
Hello, How do i set the temperature to maintain 25.0 C
1 comments:
Mr. Anderson
May 15, 2025
To set the temperature to maintain 25.0 °C on a Thermo Electron Phoenix II P1:
1. Select "Set values" in the main menu. 2. Press the function key for the set temperature (S1–S4) you want to change. 3. Activate "Change set value." 4. Use the plus/minus key to select the sign. 5. Enter 025.00 using the number keys (3 digits before and 2 after the decimal). 6. Confirm the entry when prompted to activate the value.
This answer is automatically generated
Subscribe to Our Youtube Channel
Related Manuals for Thermo Electron HAAKE Phoenix II P1
Summary of Contents for Thermo Electron HAAKE Phoenix II P1
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
1.3 Symbols used on the unit (rear) Pump connection: back flow (suction) from the external object. Pump connection: pressure to the external object. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
For this function the identification has to be activated (“Settings„ / “Control„ menu). Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Quality Assurance Quality Assurance Dear customer, Thermo Electron (Karlsruhe) implements a Quality Manage- ment System certified according to DIN/EN/ISO 9001:2000. This guarantees the presence of organizational structures which are necessary to ensure that our products are devel- oped, manufactured and managed according to our custom- ers expectations.
Contacts at Thermo Electron (Karlsruhe) GmbH Your Contacts at Thermo Electron (Karlsruhe) GmbH Please get in contact with us or the authorized agent who supplied you with the unit if you have any further questions. Thermo Electron Corporation International / Germany...
This is to certify that the tempering device which you have acquired and to which these instructions for operation refer has been tested and equilibrated by Thermo Electron (Karls- ruhe) GmbH in compliance with the regulations of a certified Quality Assurance System according to DIN ISO 9001.
EN 60601-1: 1990 (DIN VDE 0750-1 and IEC 601-1) and should not be operated in rooms used for medical pur- poses and/or in the vicinity of patients. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 13
Safety Data Sheet according to directive 91/155/EEC. • Read relevant regulations concerning dangerous materials. • Observe relevant guidelines for laboratories in your country. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 14
Complete separation means: Pull out the mains plug! Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
⇒ ⇒ Pump blocked: poss. fire danger ⇒ Or also: Excess temperature protection level not correctly set: poss. fire danger ⇒ Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
250°C. Mains cables may be changed only from autho- rized technical personnel. Warning for maintenance personnel: Use with the replacement an original Thermo Electron spare part (cable)! (Please get in contact with Thermo Elec- tron service department.) Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ...
Blocked ventilation grids lead to increased unit heating which in turn reduces the cooling capacity and thus impairs correct functioning. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
For this reason we recommend you to observe a minimum distance of approx. 1 m from such units. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Guide the unit down into the opening in a curve. Do not damage Floats, possibly easily raise. Attach the unit with 2 screws. (Order no. 003-6401) Tighten only by hand. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Symbol: Read the instruction manual! Mains switch Excess temperature setting 10 control keys to the function and menu selection LC display Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Pump outlet: pressure to the external object Mains cable (coolers with control cable) Fuses (not in conjunction with refrigerated baths), if the fuses are triggered, see chap.12.4 Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
All bath containers contain an additional tap water cooling coil (for hoses with 8 mm inner ø). The flow direction of the water can be freely selected. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Fuses (if the fuses are triggered, see chap. 12.4) Mains cable Connection for combined mains connection and control cable 19 of Phoenix Symbol: Read the instruction manual! Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Please select the proper hoses from the following table. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
8 or 12 mm ∅ which are attached to the pump nozzle A with the coupling nut E. For the isolation it is highly recommended to use the foam rubber isolation. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Hoses 9.2.2 Metal hoses Thermo Electron metal hoses (stainless steel insulated) of- fer a particularly high degree of safety and are suitable for both low and high temperatures. The metal hoses are attached directly to the nozzle A, gas- kets are not required.
The actual temperature will rise above the set temperature if the water flow is insufficient. If so in- crease the water flow. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
When a safety element causes a shut off, the si- phoning of one of the vessels cannot be prevented. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
C25P, C40P and C41P. Unfortunately SIL180 has a creeping tendency necessitat- ing the occasional cleaning of the bath cover. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 30
Their flash point is at about 10°C. Therefore, they cannot be used in accordance with the standards EN 61010 or DIN 12879. other Thermo Electron offers a range of heat transfer liquids for temperatures these temperature control applications. Synth ... : Synthetic thermal liquid with a medium life span (some months) and little smell annoyance.
Page 31
! Important ! At bath temperatures of over 200°C the usage of a heat take-off is recommended. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 32
Light- - Rubber Copper Copper metals Silicone Light- Light- Zinc metals metals Bronze Bronze 0226 0225 no sp. = no specifications Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Replenish the liquid. Reset the unit: Depress the reset button. ⇒ The unit goes to the basic condition. Repeat this action if necessary. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Hot Baht liquid or very cold bath liquids should not be drained! When certain conditions make drain- ing necessary, please act safety conscious: Wear protective clothing and protective gloves! Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The mains cable wires have the following colors: Brown Live Blue Neutral Green/Yellow= Earth Note amperage on rating plate! Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If the fuse should be triggered again after resetting, the unit probably has a defect. In this case the unit should be sent in for servicing. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If the beep is switched on, there is an acoustic signal each time you press a key. Back 39 : LCD --contrast settings Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
10 : Settings unit time/date The actual values are shown in the bottom line. dd . y y y y 33 : Input date Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Additional heating switches on again. Back 13 : Settings unit multi funct. port Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
This function only has a meaning when the optional analog interface box is connected to the 7: Settings interface RS232C interface. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Controlling can be stopped by pressing the „Stop“ key in the main menu. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
To deactivate the identification, select ”Settings” and ”Con- trol”. Switch ”Identification” to ”OFF”. To switch off the identification please see chapter 14.5 . Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
„Set values“ submenu first. The changed set value is stored permanently and is acti- vated immediately. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
A new empty line is added automatically to the table of the temperature program when a segment has been entered completely. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
With the function „Beep“ you can select whether a signal sounds after the end of each segment, after the end of each ramp or if there is no signal. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
When restarting the program, the unit heats/ cools, until the start temperature ± the set variation is reached. Then the program starts again with the first segment. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
(i.e. set and actual temperature) intersect. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 49
The times of segments no. 3 and no. 4 should be extended so that the circulator can keep the given values. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If you would like to shorten this, select „medium“ or „fast“. When using the setting „fast“ you should reckon with quicker control times. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The follower control can be activated only with attached Pt100--Sensor. It is closed, if a temperature specification via I/O port is available. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The minimum and maximum limit values that can be set de- pend on the unit combination. (operating temperature ranges see Technical Specification) Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
To restart the controller, the Stop function must be activated in the main menu, followed by the Start function. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Additional protection, e.g. of a biological sample. The cut-off point should be set as close as possible to the desired temperature value. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The set overtemperature value can be read off at any time in the ”Settings / Status” menu. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If the circulator switches off again after a short ⇒ Set value 40.00 time, return the unit for servicing! ° C ALARM Pump 17:00:00 17.11.00 Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
17:00:00 17.11.00 16.6 External fault RS232C The circulator has been switched to fault status via the interface. ⇒ Check the external system. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
⇒ The reset key must be pressed in order to start up the unit again. ALARM disappears on the display and the unit can be operated again. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If not the unit must be checked over by qualified service per- sonnel. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Do not connect external mass or voltage supply! The shorting bridge at Pin 3 and 4 must be removed before connecting the external alarm circuit. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The complete contact of the shielding within the plugs is of special importance. Insufficient contact may lead Attach shielding plane to noise penetration and result in performance errors. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The saved parameters will be listed in the first line. Changes will be done in the following line. All these transfer parameters cannot be altered via the interface. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The interfaces can be controlled by the user either via a BASIC program or a higher programming language (under DOS) or via the Windows-Terminal (under Winwows 3.1x). Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
If you have already controlled a circulator HAAKE DC50 via the PC you can use the same set of commands for the circu- lators of the Phoenix II line. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 67
20.01 (no comma!!!) Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 68
R_XT Call up time R_XD Call up date W_XD_ Select time <HH>_<MM>_<SS> W_XD_ Select date <DD>_<MM>_<YY> ” _ ” = blank Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 69
0 to 100 % lock Keyboard W_SP_0 W_SP_1 ” _ ” = blank Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 70
Before starting a segment first enter W_ASxx. Then the circulator runs to the start tem- perature of the segment. ” _ ” = blank Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 71
Answer „ XR_< program no. >_< segment no. >_< segment remain time >_ < setpoint step >_< actual ramp setpoint >_< segment end temperature > „ ” _ ” = blank Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Liquid level OK Alarm overtemperature Temperature OK Main relay missing Main relay present External control Internal control Temperature control ON Temperature control OFF Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
This means that the end temperature of segment i must be the start temperature of segment i+1. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 74
W SN6 W SP 5 185.0 205.0 240 W SA W SN7 W SP 6 205.0 205.0 180 W RS 3 Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 75
The times of segments no. 3 and no. 4 should be extended so that the circulator can keep the given values. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
(ice) on the condenser. This reduces the refrigeration output. • Low mains voltage reduces the output of the refrigeration unit. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Therefore: The units contain the ozone-friendly coolants R134a, R404A or R23. The units may however only be discarded by authorized personnel. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Unscrew the 2 screws (Order no. 003-6401). Incline the unit slightly whilst lifting it. Lift the float to avoid any damage. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Total wattage 230 V / 115 V 2500 Order no. for 230 V / 50 Hz 440--0751 for 220 V / 3 Ph / 60 Hz 440--0759 Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
I.e. with this interface you can • define set values (voltage and current input) and simul- taneously Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 83
RT1 and RT2 can be seen in the display with the associated correction values RT1 and RT2. For T1, define the temperature value at which the devi- Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 84
In order to end the entry via the analog connection, you deac- tivate the analog interface in the „Settings“ / „Interfaces“ menu. Version 3.07 HAAKE Phoenix II P1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 85
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the HAAKE Phoenix II P1 and is the answer not in the manual?
Questions and answers
Hello, How do i set the temperature to maintain 25.0 C
To set the temperature to maintain 25.0 °C on a Thermo Electron Phoenix II P1:
1. Select "Set values" in the main menu.
2. Press the function key for the set temperature (S1–S4) you want to change.
3. Activate "Change set value."
4. Use the plus/minus key to select the sign.
5. Enter 025.00 using the number keys (3 digits before and 2 after the decimal).
6. Confirm the entry when prompted to activate the value.
This answer is automatically generated