  • Page 1 ⚫ CBG2-0501-SFP-12 ⚫ CBG2-0501-SFP-12-T...
  • Page 2 Disclaimer Leonton Technologies, Co. Ltd. provides this manual without warranty of any kind, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3 Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en présence d'interférences radio. This document is the current official release manual. Please check our website (www.leonton.com) for any updated manual or contact us by e-mail (sales@leonton.com).
  • Page 4: Table Of Contents

    CONTENT OVERVIEW ............................ 1 Key Features .................................. 1 Package Contents ................................ 2 Safety Precaution ................................. 2 HARDWARE DESCRIPTION ....................... 3 Physical Dimensions ..............................3 Front Panel ..................................4 Top View ..................................4 LED Indicators ................................5 PoE Port LED Indicators ............................. 7 Dip Switch Setting ...............................
  • Page 5: Overview

    OVERVIEW This series is rated IP40 and installation by DIN Rail. Each unit of this industrial gigabit PoE compact size design for short installation space provided 4*10/100/1000Base-Tx with IEEE 802.3bt compliant ports (90W) convert to 1 dual-rate (100/1000) SFP slot, suitable for Ethernet and SFP conversion applications. In order to prevent unregulated voltage, this series provides high EFT and ESD protection.
  • Page 6: Package Contents

    Package Contents ⚫ 1 - CBG2-0501-SFP-12(-T) - Unit weight: 0.912kg ( 2.01lb), Shipping weight: 1.14kg ( 2.51lb) ⚫ 2 - Wall mounting brackets and screws ⚫ 1 - Quick installation guide Safety Precaution Attention If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input.
  • Page 7: Hardware Description

    HARDWARE DESCRIPTION Physical Dimensions Figure 2.1, below, shows the physical dimensions of CBG2-0501-SFP-12 series. (W x H x D) is 64.9mm x 110mm x 89.8mm Figure 2.1: Physical Dimensions...
  • Page 8: Front Panel

    Figure 2.2: The Front Panel Top View Figure 2.3, below, shows the top panel of the CBG2-0501-SFP-12 series switches that is equipped with one 6-pin removal terminal block connector for dual DC power inputs (9-55VDC). Figure 2.3: Top Panel View...
  • Page 9: Led Indicators

    LED Indicators There are LED light indicators located on the front panel of the industrial switch that display the power status and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1. Table 2.1: LED Indicators Color Description...
  • Page 10 Red + Blue The actual PoE Consumption of all connected working PDs budget was 71 - 90% Blinking The actual PoE Consumption of all connected (Red) working PDs budget was 91 - 100% (1 time/s) Connected to network, 10/100/1000Mbps Copper Port Green Blinking Networking is active, 10/100/1000Mbps...
  • Page 11: Poe Port Led Indicators

    PoE Port LED Indicators The LED light indicators on the PoE copper port can help the user know if an event once occurs or is happening. When the event is happening, user can verify the event from the Dual-color LED status. If the port has recovered from an event, user can verify the event from the blinking frequency of the PoE LED(5 seconds as a cycle,).
  • Page 12 • Cable Short Event When the working PD encounters a cable short event, the PoE Port LED will act cyclically as below until the port is recovered from the event: After the PoE port is recovered from the Cable Short event, the PoE LED of the port will act cyclically as below until the event indicator is clear manually: **AF/AT: Amber;...
  • Page 13: Dip Switch Setting

    Dip Switch Setting There are 3 functional DIP-switch settings in front panel, which can be used for setting the Safe PoE disable (PoE Switch) function, the PRRT (PD Remote Reset Technology) function, and SFP transmission rate. See the Figure 2.4 and description below for more details Figure 2.4: Dip Switch Setting ⚫...
  • Page 14: Relay Contact Alarm Warning

    Relay Contact Alarm Warning 2-pin 1*24VDC@1A resistive normal open on 6-pin terminal block. The relay contact alarm will be triggered when anyone of the pre-configured events occurs. User can configure the event warning for the events listed below. (Software Default: OFF) The relay contact alarm will be triggered when anyone of the listed events occurs.
  • Page 15 1000BASE-T RJ-45 Pin Assignments (Table 2.3) Crossover Cable Straight Through Cable Pin Number / Signal Pin Number / Signal Pin Number / Signal Pin Number / Signal 1 / TP0+ 3 / TP1+ 1 / TP0+ 1 / TP1+ 2 / TP0- 6 / TP1- 2 / TP0- 2 / TP1-...
  • Page 16: Cabling

    Cabling Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable between the Switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long. The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communication applications.
  • Page 17 Step 2. Insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2.7. Figure 2.7: LC Connector to the Transceiver To remove the LC connector from the transceiver, please follow the steps shown below: Step 1.
  • Page 18: Wiring The Power Inputs

    Wiring the Power Inputs Caution: Please follow the below steps to insert the power wire. Attention: Veuillez suivre les étapes ci-dessous pour insérer le câble d'alimentation. Step 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 2.10.
  • Page 19: Wiring The Fault Alarm Contact

    Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2.12. By inserting the wires, it will detect the fault status including power failure or port link failure (managed industrial switch only) and form a normally open circuit.
  • Page 20: Hardware Installation

    HARDWARE INSTALLATION Installation Steps This section will explain how to install CBG2-0501-SFP-12 series. Installation Steps Step 1. Unpack the industrial Switch from the original packing box. Step 2. Check if the DIN-Rail bracket is screwed on the industrial Switch. •...
  • Page 21 Caution: If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Attention: Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la protection fournie par l'équipement peut être altérée. Caution: The installation that the safety to any system incorporating the equipment is the responsibility of the assembler of the system.
  • Page 22: Trouble Shooting

    Check for loose power connections, power losses or surges at the power outlet. ◆ Please contact Leonton for technical support service, if the problem still cannot be resolved. ● If the industrial Switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit, please check the system’s Ethernet devices’...