ZLG CANFDNET-400U Product User Manual page 43

Rs232/485/422-can fd-bus intelligent protocol converter
Hide thumbs Also See for CANFDNET-400U:
Table of Contents

Advertisement

CANFDNET-400U
High-performance Four-channel CANFD Bus-to-Ethernet Converter User Manual
As shown in Figure 5.6, the test requires a CAN (CANFD) device in addition to a PC
to receive or transmit data. Note: In the same CAN-bus bus, the CAN baud rate of the
CAN device and the CANFDCOM-100IE converter must be the same, and the baud rate
of the serial port must be the same. Otherwise, the communication fails and the indicator
flashes red.
Conduct data conversion tests. Use the serial port debugging software to send data
by using the same serial port baud rate as the converter. Observe whether the data
received by the CAN device is consistent with the data sent. You can also send data from
the CAN device to the converter, and observe whether the data received by the serial port
software is consistent with the sent data.
If there is data transmission on one side of the bus, and the transmission is normal,
the indicator of the bus will flash green.
Figure 5.6 Communication test structure
©2021 Guangzhou ZLG Microelectronics Technology Corp.,Ltd.