Samsung AM MXVAFC Series Installation Manual page 45

Table of Contents

Advertisement

Capacity (MBH)
5
6
Model
Concealed Floor Standing
0 . 1 2
(AM✴✴✴✴NF(G)DCH/✴✴)
(0 . 2 6)
Floor Standing
(AM✴✴✴✴NPD*H/✴✴)
Ceiling
(AM✴✴✴✴NCD*H/✴✴)
V-AHU
(AM✴✴✴✴NZDCH/✴✴)
Wall mounted
0 . 2 4
(AM✴✴✴FNTDCH/✴✴)
(0 . 5 3)
Wall mounted (with EEV)
0 . 3 4
(AM✴✴✴F(H)NQDCH/✴✴)
(0 . 7 5)
Wall mounted
0 . 1 6
0 . 1 6
(0 . 3 5)
(0 . 3 5)
(AM✴✴✴✴NADKH/✴✴)
Wall mounted (with EEV)
0 . 2 2
0 . 2 2
(AM✴✴✴✴NVD*H/✴✴)
(0 . 4 9)
(0 . 4 9)
Wall mounted
0 . 2 4
(AM✴✴✴KNTDCH/✴✴)
(0 . 5 3)
Wall mounted (with EEV)
0 . 2 4
(0 . 5 3)
(AM✴✴✴KNQDCH/✴✴)
Wall mounted (with EEV)
(AM✴✴✴MNQDCH/✴✴)
ERV plus
(AM✴✴✴✴NKDEH/✴✴)
Hydro Unit HE
(AM✴✴✴✴NBDEH/✴✴)
MCU (MCU-S✴✴NE✴✴N)
f If AHU Kit is included among the indoor units, add 0 . 0 18kg(0 . 0 4lb) of refrigerant for every 1MBH of AHU capacity
f
increase .
f Method to calculate total amount of additional refrigerant
f
- Amount of additional refrigerant depending on the pipe length (ⓐ)
- Amount of additional refrigerant for each indoor unit (ⓑ) = ∑(Amount of additional refrigerant for each connected
indoor unit) ❇ Refer to the table
- Total amount of additional refrigerant = ⓐ+ⓑ
❋ ❋ Sum of total amount of additional refrigerant and the basic amount of refrigerant should not exceed 100kg (220lb) . If the
refrigerant exceeds 100kg (220lb), separate the module so that weight of the refrigerant doesn't exceed 100kg (220lb) .
Ex . ) For AM180✴✴✴, basic amount of refrigerant is 8 . 7 kg (19 . 1 lb), therefore total amount of additional refrigerant
(ⓐ+ⓑ) should not exceed 91 . 3 kg (200 . 9 lb) .
f Example of refrigerant calculation for C/O models
f
Size of liquid pipe
Classification
[mm (inch)]
Ø6 . 3 5 (Ø1/4)
Ø9 . 5 2 (Ø3/8)
Liquid pipe (ⓐ)
Ø12 . 7 0 (Ø1/2)
7
9
12 15 18 19 20 24 27 28 30 32 36 38 42 48 54 60 72 76 96 110 170
0 . 2 2
0 . 2 2
0 . 3 2
0 . 3 2
(0 . 4 9)
(0 . 4 9)
(0 . 7 1)
(0 . 7 1)
0 . 3 9
0 . 3 9
(0 . 8 6)
(0 . 8 6)
0 . 3 3
0 . 5 0
0 . 5 0
(0 . 7 3)
(1 . 1 0)
(1 . 1 0)
0 . 2 4
0 . 2 4
0 . 3 6
0 . 3 6
0 . 3 6
(0 . 5 3)
(0 . 5 3)
(0 . 7 9)
(0 . 7 9)
(0 . 7 9)
0 . 3 4
0 . 3 4
0 . 5 1
0 . 5 1
0 . 5 1
(0 . 7 5)
(0 . 7 5)
(1 . 1 2)
(1 . 1 2)
(1 . 1 2)
0 . 1 9
0 . 2 5
0 . 2 5
0 . 5 2
0 . 5 2
(0 . 4 2)
(0 . 5 5)
(0 . 5 5)
(1 . 1 5)
(1 . 1 5)
0 . 2 5
0 . 3 4
0 . 3 4
0 . 7 1
0 . 7 1
0 . 7 1
(0 . 5 5)
(0 . 7 5)
(0 . 7 5)
(1 . 5 7)
(1 . 5 7)
(1 . 5 7)
0 . 3 2
0 . 3 2
0 . 4 9
0 . 4 9
0 . 4 9
(0 . 7 1)
(0 . 7 1)
(1 . 0 8)
(1 . 0 8)
(1 . 0 8)
0 . 3 2
0 . 3 2
0 . 4 9
0 . 4 9
0 . 4 9
(0 . 7 1)
(0 . 7 1)
(1 . 0 8)
(1 . 0 8)
(1 . 0 8)
Length [m (ft)]
35 (114 . 8 )
50 (164 . 0 )
15 (49 . 2 )
0 . 6 9
(1 . 5 2)
0 . 5 6
0 . 5 6
0 . 9 5
(1 . 2 3)
(1 . 2 3)
(2 . 0 9)
0 . 8 3
0 . 8 8
1 . 1 8
1 . 2 7
(1 . 8 3)
(1 . 9 4)
(2 . 6 0)
(2 . 8 0)
0 . 5 2
(1 . 1 5)
0 . 7 1
(1 . 5 7)
0 . 6 8
(1 . 5 0)
0 . 6 0
(1 . 3 2)
0 . 5 0 (1 . 1 0)
Unit amount of
Amount of
refrigerant [kg/m
additional
(lb/ft)]
refrigerant [kg (lb)]
0 . 0 2 (0 . 0 13)
0 . 7 (1 . 4 9)
0 . 0 6 (0 . 0 40)
3 . 0 (6 . 5 6)
0 . 1 25 (0 . 0 84)
1 . 8 75 (4 . 1 3)
500
CMH
1 . 8 5
(4 . 0 8)
1 . 6 9
1 . 6 9
(3 . 7 3)
(3 . 7 3)
0 . 1 1
(0 . 2 4)
0 . 7 0
1 . 2 0
(1 . 5 4)
(2 . 6 5)
Total amount
of additional
refrigerant [kg (lb)]
①×②
∑(①×②)
5 . 5 75 (12 . 1 9)
1000
CMH
0 . 3 6
(0 . 7 9)