Samsung MC18AC2-09 Owner's Instructions Manual
Samsung MC18AC2-09 Owner's Instructions Manual

Samsung MC18AC2-09 Owner's Instructions Manual

Multi-split type room air conditioner ( cool )
Hide thumbs Also See for MC18AC2-09:

Advertisement

ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT
CONDIZIONATORE D'ARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE
RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG
äéåçÄíçõâ ÇéáÑìòçõâ äéçÑàñàéçÖê íàèÄ åìãúíà-ëèãà
E S F I P D G R DB98-03915A(5)
OWNER'S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
ISTRUZIONI PER L'USO
MANUAL DE INSTRUÇÕES
GEBRAUCHSANWEISUNG
àçëíêìäñàü èéãúáéÇÄíÖãü
Indoor unit
AM14B1(B2)E07
AM18B1(B2)E09
AM20B1(B2)E06
AM20B1(B2)E09
AM26B1(B2)E07
AM26B1(B2)E12
AM18B1(B2)B09
AM26B1(B2)B13
AM26B1(B2)B13A
AM27B1(B2)C07
AM27B1(B2)C13
MC18AC2-09
MC19AC2-07
MC19AC2-12
MC24AC2-12
MC26AC2-07
MC26AC2-12
MULTI-SPLIT TYPE ROOM AIR CONDITIONER
CLIMATISEUR DE TYPE MULTIPLE
AR CONDICIONADO MULTI SPLIT

Outdoor unit

UM14B1(B2)E2
UM18B1(B2)E2
UM20B1(B2)E3
UM26B1(B2)E3
UM18B1(B2)B2
UM26B1(B2)B2
UM26B1(B2)B2A
UM27B1(B2)C3
MC18AC2X
MC19AC2X
MC24AC2X
MC26AC2X
( Cool )
( Refrigeración )
( Refroidissement )
( Raffreddamento )
( Refrigeração )
( Kühlen )
í ( éı·ʉÂÌË )

Advertisement

Table of Contents
loading

Summary of Contents for Samsung MC18AC2-09

  • Page 1: Outdoor Unit

    MULTI-SPLIT TYPE ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT CLIMATISEUR DE TYPE MULTIPLE CONDIZIONATORE D’ARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE AR CONDICIONADO MULTI SPLIT RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG äéåçÄíçõâ ÇéáÑìòçõâ äéçÑàñàéçÖê íàèÄ åìãúíà-ëèãà E S F I P D G R DB98-03915A(5) OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION...
  • Page 2: Safety Precautions

    WARNING URING OPERATION ISPOSING OF THE UNIT THERS Register your product at www.samsung.com/global/register Risk of electric shock. Can cause injury or death. remote electric power supplies before servicing, installing or cleaning. This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
  • Page 3: Table Of Contents

    Contents REPARING YOUR AIR CONDITIONER Safety Precautions ........2 View of the Unit .
  • Page 4: View Of The Unit

    View of the Unit The design and shape are subject to change according to the model. Indoor Unit Air filter (under the grille) Timer indicator STANDARD indicator NATURE indicator For details on the 5 Way, refer to page 9. Air Inlet Air flow blades (outlet) Remote Control Sensor SAVING indicator...
  • Page 5 Indoor Unit Air filter (under the grille) STANDARD indicator NATURE indicator POWER indicator For details on the 5 Way, refer to page 9. Outdoor Unit The design and shape are subject to change according to the model. Air Inlet(Rear) Air Outlet Air Inlet Air flow blades (outlet) On/Off &...
  • Page 6: Remote Control-Buttons And Display

    Remote Control - Buttons and Display Remote control transmission indicator Operating mode AUTO, DRY, Temperature setting Turbo mode Sleep mode Fan speed Air flow direction On Timer setting Off Timer setting Battery discharge indicator 5 Way selection button COOL, FAN) Mode selection button (AUTO, COOL, DRY, FAN) Temperature adjustment...
  • Page 7: Getting Started

    etting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features.
  • Page 8: Inserting The Remote Control Batteries

    Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
  • Page 9: Way Function

    5 Way Function You can select the 5 Way function with operating mode of the air conditioner for more comfortable circumstances. You can use the 5 Way function with the indoor unit as well as the remote control. Thus, you can use this function even though you have lost your remote control.
  • Page 10: Selecting The Automatic Operating Mode

    Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. If necessary, press the (On/Off) button.
  • Page 11: Cooling Your Room

    Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 12: Changing The Room Temperature Quickly

    Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible. You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
  • Page 13: Removing Excess Humidity

    Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 14: Airing Your Room

    Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 15: Adjusting The Air Flow Direction Vertically

    Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. Press the SWING button one or more times as required.
  • Page 16: Setting The On Timer

    Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the ON TIMER button one or more times until the required time is displayed.
  • Page 17: Setting The Off Timer

    Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the OFF TIMER button one or more times until the required time is displayed.
  • Page 18: Setting The Sleep Timer

    Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. If you wish to switch the unit off at a specific time, refer to page 17.
  • Page 19: Operating Recommendations

    Operating Recommendations Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, Be sure which model you have purchased because some air conditioners do not restart automatically.
  • Page 20: Temperature And Humidity Ranges

    Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... High temperatures Low temperatures High humidity levels Mode Outdoor Temperature Cooling 21°C to 43°C approx. Drying 18°C to 43°C approx.
  • Page 21: Solving Common Problems

    Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem The air conditioner does not operate at all The air conditioner does not operate with the remote control No beep is heard when you press (On/Off) on the remote control...
  • Page 22: Installing A Filter (Option)

    Installing a Filter (Option) Deodorizing filter Bio-Pure Filter The air conditioner can be fitted with a deodorizing and Bio-Pure filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used.
  • Page 23: Technical Specifications

    Technical Specifications Indoor unit Outdoor unit AM14B1(B2)E07 UM14B1(B2)E2 AM18B1(B2)E09 UM18B1(B2)E2 AM20B1(B2)E06 UM20B1(B2)E3 AM20B1(B2)E09 AM26B1(B2)E07 UM26B1(B2)E3 AM26B1(B2)E12 MC18AC2-09 MC18AC2X MC19AC2-07 MC19AC2X MC19AC2-12 MC24AC2-12 MC24AC2X MC26AC2-07 MC26AC2X MC26AC2-12 AM18B1(B2)B09 UM18B1(B2)B2 AM26B1(B2)B13 UM26B1(B2)B2 AM26B1(B2)B13A UM26B1(B2)B2A AM27B1(B2)C07 UM27B1(B2)C3 AM27B1(B2)C13 Power Supply 220-240V~, 50Hz 220V~, 60Hz 208-230V~, 60Hz...
  • Page 24 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ: ELECTRONICS...