Listing and Code Approvals

A. Appliance Certification
Model
3100 Millennium AU Wood Appliance
Number:
Laboratory: HRL Technology
Report No: HCMG/12/043A
Type: Hardwood only at 25% dry basis
Standard: AS/NZS 2918:2001
B. BTU & Efficiency Specifications
Overall Average Efficiency
Burning Hardwood (AS/NZS
Average Particulate
Emission Factor Burning
Hardwood (AS/NZS 4013)
Maximum Average Heat
Output Burning Hardwood
Wetback
Vent Size: 6 inches
Firebox Size: 2 cubic feet
Recommended Wood
Length:
Fuel Orientation: Front-to-Back
Approved Fuel
NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their
specifications and/or price without notice.
The Quadra-Fire 3100 Millennium Australian Wood Appliance is Hardwood Certified. Particulate Emissions equaling 1.4 g/
This wood appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this wood appliance in a manner inconsistent with operating instructions in this manual.
8
All manuals and user guides at all-guides.com
71%
4012)
1.4 g/kg
7.1kW
Wetbacks are NOT an
approved option and
must be fitted.
16 inches
Hardwood only with a
Moisture content less
than 25% (dry basis)
kg with a space heating efficiency of 71%.
C. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
Installation and use of any damaged appliance.
Modification of the appliance.
Installation other than as instructed by Hearth &
Home Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling
all components.
Operating appliance without legs attached (if
supplied with appliance).
Do NOT Over fire - If appliance or chimney connector
glows, you are over firing.
Any such action that may cause a fire hazard.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
7033-362C
WARNING
11/21