3 After mounting the unit, remove the sling from the unit by pulling
1 side of the sling.
2.1.2
To remove the accessories from the
outdoor unit
1 Lift the outdoor unit. See
"2.1.1 To handle the outdoor unit" on
page 4.
2 Remove the accessories at the bottom of the package.
a
b
c
a
Outdoor unit installation manual
b
Fluorinated greenhouse gases label
c
Multilingual fluorinated greenhouse gases label
d
Energy label
e
Unit mounting plate
f
Bolts, nuts, washers, spring washers and wire clamp
3

Preparation

3.1

Preparing the installation site

WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
3.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
>250
>350
b
a
(mm)
a
Air outlet
b
Air inlet
RRGA04~08DAV3
ROTEX HPSU Bi-Bloc Ultra
4P496756-1B – 2018.07
d
e
f
ENERG
ENERG
Y
IJA
Y
IJA
IE
IA
IE
IA
b
>250
a
>250
(mm)
INFORMATION
In sound sensitive areas (e.g. near a bedroom), you can
install the low sound cover (EKLN08A1) to decrease the
operation noise of the outdoor unit. If you install it, mind the
following spacing guidelines:
a
0
> 1 0
a Low sound cover
The outdoor unit is designed for outdoor installation only, and for the
following ambient temperatures:
Cooling mode
Heating mode
3.1.2
Additional installation site requirements
of the outdoor unit in cold climates
In areas with low ambient temperatures and high humidity, or in
areas with heavy snowfall, remove the suction grille to ensure proper
operation.
Non-exhaustive list of areas: Austria, Czech Republic, Denmark,
Estonia, Finland, Germany, Hungary, Latvia, Lithuania, Norway,
Poland, Romania, Serbia, Slovakia, Sweden, ...
1 Remove the screws holding the suction grille.
2 Remove the suction grille, and dispose of it.
3 Reattach the screws to the unit.
1
3
2
a
Suction grille
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
3 Preparation
>100
a
(mm)
10~43°C
–25~25°C
a
Installation manual