Connecting
5.1
Grounding
Note
Grounding is required for voltages higher than protective extra low voltage.
With voltages of > 50 V AC or 120 V DC, the device has to be grounded. Active parts must
not be grounded or connected to higher voltage parts.
5.2
Conductor cross-sections
5.3
Connections
The contact blocks and lampholder are fitted with IEC 60760-compliant flat connectors which
can also be used as solder connections.
All connectors are fitted with two tabs to allow loop-through.
5.4
Solder pin connection
The command point comprises the actuator (e.g. 3SB2 pushbutton, illuminated pushbutton
or indicator light) which is mounted in the front plate, and a contact block and a lampholder
which are soldered to the PCB.
3SB2 pushbuttons and indicator lights
Configuration Manual, 05/2020, A5E43900767002A/RS-AA/001
3SB2
2 x (0.5 ... 1.5) mm²
2 x (2.8 ... 0.8) mm
5
23