SIZE OF CABINET APERTURE
Cut-out a hole in the cabinet as illustrated in FIG. 2 - PG. 123 depending on model to install.
The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit.
The cabinet aperture must be perfectly squared and aligned.
If there are apertures for cabinet ventilation, prevent flammable materials from entering these.
Models PI8621A, PI8621S and PI8621R are modular.
It is possible to connect from 1 to 5 appliances in series.
ALWAYS RESPECT THE DISTANCE BETWEEN ONE CABINET APERTURE AND ANOTHER (PG. 127).

CONNECTING TO GAS SUPPLY

CHECK THESE SPECIFICATIONS BEFORE CONNECTING THE APPLIANCE TO
THE GAS CYLINDER /BOTTLE. THE PRESSURE REGULATORS CONNECTED
BETWEEN THE GAS CYLINDER AND APPLIANCE MUST CONFORM WITH THE
CATEGORIES GIVEN IN THE TABLE BELOW.
This appliance is designed for running off the following types of gas at the corresponding operating pressures. The gas
category (or categories) of the appliance is given on the specifications label affixed to the appliance.
CATEGORY AND COUNTRY OF DESTINATION
I3B/P(30)
AT BE DE DK FI GB NL NO PT SE SI
I3+ (28-30/37)
BE CH ES FR GB IE IT PT SI
MODEL
MO8801D - MO8801S - MO8821D
MO8821S - PI8621A
PI8621S
PI8621R
MO0911 - MO0911P - MO0917D - MO0917S
MO0921D - MO0921S - MO0927D - MO0927S
MO8302 - MO8322 - MO8342
MO8362 - - MO9202D - MO9202S
MO9222D - MO9222S
MO9702L - MO9702R - MO9722L - MO9722R
PI0909 - PI0909P - PI2212 - PI2212P
PI8002 - PI8022 - PI8042 - PI8062
PI8802D - PI8802S - PI8822D - PI8822S
PI8842D - PI8842S - PI8862D - PI8862S
MO8952 - MO9122
7103 - 7123 - 8103 VD - 8103 VDM
8123 VD - 8123 VDM - 8203 - 8203M - 8223
8223M - MO0903 - MO8303 - MO8323
PI0913 - PI0913A - PI9003 - PI9023
PI9803R - PI9803L - PI9823R - PI9823L
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butane (G30)
37 mbar Propane (G31)
TOTAL NOMINAL THERMAL
CAPACITY
kW - gr/h
1,0 - 73
1,8 - 131
2,2 - 160
2,8 - 204
3,2 - 233
3,6 - 262
3,8 - 277
GAS PRESSURE
AIR VOLUME REQUIRED FOR
COMBUSTION
m
/h
3
2,0
3,6
4,4
5,6
6,4
7,2
7,6