Hypro 9500 Series Installation, Operation, Repair Instructions

Hypro 9500 Series Installation, Operation, Repair Instructions

Direct and gas engine-driven centrifugal pumps

Advertisement

Quick Links

Menu
Installation, Operation, Repair Instructions
Hypro Centrifugal Pumps handle big, high-capacity
farm spraying jobs with ease. Use them for spraying
liquid fertilizers and other chemicals, including wettable
powder slurries for weed control. Make short work of
other farm jobs - filling nurse tanks, watering seed
beds, and transferring liquids.
SERIES 9200
Cast Iron, Stainless Steel
Pedestal-Mount Centrifugal Pumps
SERIES 9500P
Polypropylene
Flange-Mount Centrifugal Pumps
SERIES 1500
Close-Coupled, Gas Engine-Driven
Centrifugal Pumps
Series 9200, 9500 and 1536 through 1551
Direct and Gas Engine-Driven Centrifugal Pumps
Description
Available in a variety of models, including lightweight
polypropylene (pump portion only) pumps for resistance
to corrosive liquids such as acid-based fertilizers.
This form replaces Form L-0300C. For individual
parts breakdowns, product outlines and performance
specifications, visit www.hypropumps.com.
See chart below for new form numbers.
Pump/Model
Number
9202C, 9202S,
9262C-C and 9262S-C ...........L-0300AG-1
9203C, 9203C-R,
9203S, 9203S-R,
9263C-C and 9263S-C ...........L-0300AG-2
9203C-SP, 9203S-SP,
9263C-C-SP, 9263S-C-SP.......L-0300AG-3
9203C-R-SP
and 9263C-CR-SP ................. L-0300AG-4
9203P-S
and 9253P-C.......................... L-0300AG-5
9204C......................................L-0300AG-6
9205C......................................L-0300AG-7
9205C-SP
and 9205C-BSP ......................L-0300AG-8
9206C and 9206S ...................L-0300AG-9
9513P................................... L-0300AG-10
1521, 1536, 1537, 1538,
1539 and 1540. .....................L-0300AG-11
1522C-65SP, 1536-SP, 1537-SP, 1538-SP,
1539-SP and 1540-SP...........L-0300AG-12
1550, 1551 and 1552 Series...L-0300AG-13
Form
L-0300AG
6/11, Rev. B
New Form
Number

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9500 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hypro 9500 Series

  • Page 1 L-0300AG 6/11, Rev. B Installation, Operation, Repair Instructions Description Hypro Centrifugal Pumps handle big, high-capacity Available in a variety of models, including lightweight farm spraying jobs with ease. Use them for spraying polypropylene (pump portion only) pumps for resistance liquid fertilizers and other chemicals, including wettable to corrosive liquids such as acid-based fertilizers.
  • Page 2: Safety Information

    Environmental Protection Agency Licensing. Drive Source Installation This manual will cover the installation of the basic drive configurations available for Hypro direct-drive centrifugal pumps. Consult the manufacturer of your tractor, motor or engine for additional information. Read all instructions and general safety information before attempting to install or operate the pump.
  • Page 3 Belt/Pulley Drive Installation (cont'd.) To figure proper diameter of pump pulley, multiply motor/engine rpm by diameter of the motor/engine pulley and divide that figure by desired pump speed. Push the belt midway between the pulleys, check Pump Motor RPM x Motor Pulley Size the deflection (d) Pulley Size Desired Pump Speed...
  • Page 4: Operation And Maintenance

    Direct Drive - Flange Mount Installation GAS ENGINE MOUNT — Model 9513P fits most 5 hp gas engines with flange mount and 3/4" shaft. To install pump onto gas engine, first apply anti-seize compound to gas engine shaft and to inside of pump hollow shaft.
  • Page 5: Repair Instructions

    Repair Instructions Recommended repair tools for use with these instructions: Always flush pump with water, or neutralizing agent, Cleanup Of Pump Housing before servicing. 1. Using the circular bottle-type wire brush with air or hand Pump Housing Disassembly (All Models) drill, clean the discharge port, suction port and the sealing areas of the o-ring on the pump casing and mounting In most cases, seal replacement requires disassembly of only...
  • Page 6: Plumbing Installation

    Plumbing Installation Centrifugal Plumbing Hook-up REF. DESCRIPTION Tank Lid Vent Line #3430-0456 Jet Agitator Shut-off Ball Valves Centrifugal Pump Spray Control Console Centrifugal Pump Control Manifold Boom Valve Electromagnetic Flowmeter Compact Jet Turret Nozzle Body Form L-0300AG (6/11, Rev. B) - 6 -...
  • Page 7 In addition to the proper suction plumbing, a vent line For rapid response and reliability, we recommend should be installed to assist in priming. Use a Hypro electric plunger valves be used for boom control. Vent Line Kit 3430-0456. The vent line will help to The valves should be sized accordingly to minimize prevent air locks and allows air to bleed off to the tank.
  • Page 8 Contact Hypro Service Department at 800-468-3428 to receive a Return Merchandise Authorization number (RMA#). Returns are to be shipped with the RMA number clearly marked on the outside of the package. Hypro shall not be liable for freight damage incurred during shipping. Please package all returns carefully. All products returned for warranty work should be sent shipping...

This manual is also suitable for:

9200 series1550 series1551 series1552 series9202c9202s ... Show all

Table of Contents