Download Print this page
LEGRAND 0 489 32 Manual

LEGRAND 0 489 32 Manual

Pir lighting management sensor - high ceiling areas

Advertisement

Quick Links

PIR lighting management sensor - High ceiling areas
1. USE
This device allows a light source to be controlled automatically by
detecting movement in a monitored area.
It can be installed in high ceiling areas (gymnasium, storage area, etc).
Motion sensor with 360° detection angle.
Detection type: infrared (PIR)
Mounting type: ceiling
2. TECHNICAL CHARACTERISTICS
Voltage: 100 - 240 V~
Frequency: 50/60 Hz
No-load power consumption: 0.6 W
Output via normally open contact connected to the phase
Drilling diameter: 122 mm without flush-mounting box
Wiring: 2 x 2.5 mm
2
Number of terminals: 4
Terminal type: screwless
Stripping length: 8 mm
Weight: 230 g
Impact resistance: IK04
Penetration by solid and liquid matter: IP55
Usage temperature: - 25°C to + 45°C
Storage temperature: - 25°C to + 70°C
230 V~
2000 W
8.5 A
1000 VA
110 V~
1000 W
8.5 A
500 VA
1 - Halogen bulbs
2 - ELV halogen, compact fluorescent and fluorescent bulbs with
separate electronic ballast
3 - ELV halogen, compact fluorescent and fluorescent bulbs with
separate ferromagnetic ballast
4 - Fluorescent tubes
Technical data sheet: S000081479EN_2
IP66 with cable gland
4.3 A
1000 VA
4.3 A
10x(2x36 W)
4.3 A
500 VA
4.3 A
5x(2x36 W)
Updated: 06/09/2022
CONTENTS
1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Technical characteristics. . . . . . . . . . . . . . . . .1
3. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
5. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6. Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8. Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
9. Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . .7
10. Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
11. Standards and certifications . . . . . . . . . . . . .7
12. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .8
2. TECHNICAL CHARACTERISTICS (continued)
Products approved for 40,000 operations
Mains zero breaking: in order to limit the effect of induced currents on
cut-off relays by fluorescent loads in particular, this sensor breaks the
voltage at mains zero. Switching occurs when the voltage is at point 0
which ensures a longer life for sources and for the sensor.
LEARN LED
Sensor/PIR
sensor
4.3 A
250 W
1 A
250 W
4.3 A
125 W
1 A
125 W
5 - Compact fluorescent bulbs with built-in electronic ballast
6 - Compact fluorescent bulbs with built-in ferromagnetic ballast
7 - LED bulbs
8 - Contactor
Cat. No(s): 0 489 32
LEARN button
Light level
cell
Detection
LED
1 A
250 W
1 A
500 VA
1 A
125 W
1 A
250 VA
Created: 31/03/2014
Page
2.1 A
1/8

Advertisement

loading

Summary of Contents for LEGRAND 0 489 32

  • Page 1 PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 CONTENTS Page 1. Use ........1 2.
  • Page 2 PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 3. DIMENSIONS 4. CONNECTION 4.1 Wiring with auxiliary control:  8.5 A max.  100 m max. 4.2 Wiring for several loads connected in parallel 8.5 A 8.5 A...
  • Page 3: Installation

    PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 4. CONNECTION (continued) 5.1 Wiring with timer 0 047 04 4 126 02 8.5 A S- S+ max. With this wiring, the configuration tool must be on "Pulse" (see paragraph 8. Settings).
  • Page 4: Operation

    PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 5. INSTALLATION (continued) 7. OPERATION 5.2 Sensor positioning Manual ON/Auto OFF mode: Pressing the auxiliary control allows the load to be switched on or off manually. If the control is not pressed, the sensor will cut off the load at the end of the time delay or when the light level threshold has been reached.
  • Page 5 PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 8. SETTINGS 7. OPERATION (continued) 8.1 Detection parameters 7.2 Several sensors connected to a single load Sensor parameter Default Modifiable Configuration value parameters tools 0 882 30 0 882 35...
  • Page 6 In combination with configuration tool 0 882 40, the Legrand Close Up smartphone app can be used to view and modify all the detector Eye function: Value 0 (eye on configuration tool 0 882 30) is parameters with online help.
  • Page 7 PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 11. PERFORMANCE 9. CARE Keep the lens clean. Height Clean the surface with a cloth. Do not use: acetone, tar-removing cleaning agents or trichloroethylene. 2.5 m Resistant to the following products: - Hexane (En 60669-1)
  • Page 8: 12. Troubleshooting

    PIR lighting management sensor - High ceiling areas Cat. No(s): 0 489 32 12. TROUBLESHOOTING PROBLEM CAUSES SOLUTIONS Lighting stays on when there is no-one present Some sources of interference, such as air 1- Reduce the sensitivity level currents, vibrations and radiators, can cause...