ver 2023.01.03E
Current Limit Time-out
or Controller too hot
Park Brake Fault
Drive Inhibit
Speed Pot Fault
Motor Voltage Fault
Other error
Mobility Scooter
OWNER'S MANUAL
Meaning
The motor has been exceeding its
maximum current rating for too long.
• The scooter may have stalled. Turn the
controller o , leave for a few minutes
and turn back on again.
• The motor may be faulty. Check the
motor and associated connections and
wiring.
Either a park brake release switch is active
or the park brake is faulty.
• Check the park brake and associated
connections and wiring.
• Ensure any associated switches are in
their correct positions.
Either a Stop function is active or a
Charger Inhibit or OONAPU condition has
occurred.
• Release the Stop condition (seat raised
etc.)
• Disconnect the Battery Charger.
• Ensure the throttle is in neutral when
turning the controller on.
• The Throttle may require re-calibration.
The throttle, speed limit pot, SRW or their
associated wiring may be faulty.
• Check the throttle and speed pot and
associated connections
and wiring.
The motor or its associated wiring is faulty.
• Check the motor and associated
connections and wiring.
The controller may have an internal fault.
• Check all connections & wiring.