Archgard 3600-DVTR24N-2 User's Installation, Operation And Maintenance Manual

Direct vented top or rear vent gas room heater

Advertisement

Quick Links

WARNING: If the information in this manual is
not followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Installer: Please leave this manual with the appliance owner for future reference
3600
3600
For use with natural gas or propane*
USERS' INSTALLATION
OPERATION AND
MAINTENANCE MANUAL
This appliance may be installed in an
af t er m ar k et
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
*Conversion kit required for Propane use
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
-
dvtr24n
-
dvtr24n
Direct Vented
Top or Rear Vent
Gas Room Heater
pe r m an e nt l y
-
2
-
2
l o ca t e d,
200-1905
Sept 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3600-DVTR24N-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard 3600-DVTR24N-2

  • Page 1 3600 dvtr24n 3600 dvtr24n Direct Vented Top or Rear Vent Gas Room Heater For use with natural gas or propane* USERS’ INSTALLATION OPERATION AND MAINTENANCE MANUAL WARNING: If the information in this manual is not followed exactly, fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 3 Thank you for purchasing the 3600-DVTR24N-2 Zero Clearance Direct Vented Fireplace Gas Heater. The Optima 3600-DVTR24N-2 is one of the most advanced direct vented zero clearance gas heaters on the market. It is designed using the latest technology and manufactured to the highest quality.
  • Page 4: Table Of Contents

    Horizontal Venting Instructions Vertical Venting Instructions Operation Instructions - Safety Information Operation Instructions - Start Up & Shut Down Procedures Maintenance Troubleshooting 32 - 33 Servicing 34 - 35 Important Information Replacement Parts List 37 - 38 Archgard Warranty Warranty Registration Card...
  • Page 5 3600-DVTR24N-2 STATE OF MASSACHUSETTS REQUIREMENTS (G1-0813-71) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential pur-...
  • Page 6: Caution & Safety Information

    This gas appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. FOR YOUR SAFETY - Do not install or operate your Archgard Optima 3600 Direct Vent Gas Fireplace without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Archgard Industries Warranty and may prove hazardous.
  • Page 7: General Information

    This appliance is tested and certified to the following US and Canadian gas appliance standards. - ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heaters, - CAN/CGA-2.17-M91 Gas-Fired Appliance fo Use at High Altitudes Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 8: Appliance Dimensions

    3600-DVTR24N-2 APPLIANCE DIMENSIONS...
  • Page 9: Installation Clearances

    3600-DVTR24N-2 INSTALLATION CLEARANCES MANTLE & SIDEWALL CLEARANCES CORNER FRAME DIMENSIONS Mantle Height from Floor (B) Mantle Depth (A) 40" (1016 mm) 12" (305 mm) 39" (991 mm) 10-5/16" (262 mm) 38" (965 mm) 8-9/16" (217 mm) 37" (940 mm) 6-7/8" (175 mm) 36"...
  • Page 10: Electrical Connections, Fan System

    WARNING: Before starting, make certain the power supply is turned OFF. The 3600-DVTR24N-2 comes complete with a temperature activated fan and rheostat installed and wired to an internal junction box. The heat sensor is factory set to close the circuit to the...
  • Page 11: Glass Door Removal

    ❖ If the glass door is damaged, it must be replaced with another glass door certified for this ❖ appliance. Replacement glass doors are available through your Archgard dealer (See Replacement ❖ Parts page 36) Replacing the Glass Door Check the condition of the glass and the gasket before installing door.
  • Page 12: Log Placement

    3600-DVTR24N-2 LOG PLACEMENT The Archgard pan burner and fiber logs are designed to give a realistic fire package, and are created to maintain their appearance from the day they were originally installed. Care must be given when first installing the logs and when removed for servicing, as they can be damaged or broken if not handled properly.
  • Page 13 3600-DVTR24N-2 LOG PLACEMENT - CONTINUED STEP 1 - PLACE REAR LOG ON PINS AND BURNER AS SHOWN (Shown with optional brick liner) STEP 2 - PLACE RIGHT REAR LOG ON PIN AND LOG AS SHOWN (Shown with optional brick liner)
  • Page 14 3600-DVTR24N-2 LOG PLACEMENT - CONTINUED STEP 3 - PLACE FRONT RIGHT LOG ON PINS AND BURNER AS SHOWN STEP 4 - PLACE FRONT LEFT LOG ON PINS AS SHOWN (Shown with optional brick liner)
  • Page 15 3600-DVTR24N-2 LOG PLACEMENT - CONTINUED STEP 5 - PLACE LEFT REAR LOG AS SHOWN STEP 6 - PLACE FRONT CENTER LOG AS SHOWN (Shown with optional brick liner)
  • Page 16 3600-DVTR24N-2 LOG PLACEMENT - CONTINUED STEP 6 - PLATINUM EMBERS SHOULD BE PLACED ON BURNER AS SHOWN (Shown with optional brick liner)
  • Page 17: Installation Instructions

    3600-DVTR24N-2 INSTALLATION INSTRUCTIONS PRECAUTIONS This appliance must be installed by a qualified gas installer and the installation conform to ❖ the installation codes. This appliance needs fresh air for safe operation and must be installed so there are ❖ provisions for adequate ventilation air. Provide adequate clearance around air openings of the appliance.
  • Page 18 3600-DVTR24N-2 INSTALLATION INSTRUCTIONS GAS CONNECTIONS Have your gas supplier or a qualified gas fitter run a gas supply line into the gas fireplace. The line must be properly sized and fitted according to the installation codes. Upstream of the supply connection, the fitter shall provide a manual shut-off valve.
  • Page 19 3600-DVTR24N-2 INSTALLATION INSTRUCTIONS GAS CONNECTIONS - CONTINUED The minimum permissible gas supply pressure is 4.5 in. w.c. (1.12 kPa) for natural gas and 11.0 in. w.c. (2.74 kPa) for propane. Maximum gas supply pressure should never exceed 7 in. w.c. (1.74 kPa) or ½...
  • Page 20: Optional Wall Switch Or Thermostat

    3600-DVTR24N-2 OPTIONAL WALL SWITCH OR THERMOSTAT If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be wired as shown in Fig 1. This will allow the original on/off rocker switch to be used incase the device that is mounted to the wall is inoperable.
  • Page 21: Top / Rear Vent Conversion

    3600-DVTR24N-2 TOP / REAR VENT CONVERSION The appliance is easily converted from top vent to rear vent. The steps for converting are as follows: 1. Remove the top vent outer shell cover (#1) 2. Remove the top vent heat shield cover (#2) 3.
  • Page 22: Allowable Termination Locations

    3600-DVTR24N-2 ALLOWABLE TERMINATION LOCATIONS...
  • Page 23: Approved Vent Components

    The appliance will not function without being connected to a proper venting system. This appliance may only use direct vent system supplied by Archgard Industries or Simpson Dura- Vent direct vent systems with the appropriate adaptor dependent upon the venting guidelines within this manual.
  • Page 24 ARCHGARD VENTING COMPONENTS PART # DESCRIPTION 999-DV-TVK3 Archgard Flex Vent Kit with 36” (914 mm) vent length (includes 999-DV-HTC) 999-DV-TVK5 Archgard Flex Vent Kit with 60” (1.52 M) vent length (includes 999-DV-HTC) 999-DV-TVK10 Archgard Flex Vent Kit with 120” (3.05 M) vent length (includes 999-DV-HTC)
  • Page 25 3600-DVTR24N-2 SELKIRK PARTS LIST PART # DESCRIPTION 4" x 6 " LENGTHS 1604006 4DT- 6 DIRECT-TEMP 6" PIPE LENGTH 1604006B 4DT- 6B DIRECT-TEMP 6" PIPE LENGTH BLACK 1604009 4DT- 9 DIRECT-TEMP 9" PIPE LENGTH 1604009B 4DT- 9B DIRECT-TEMP 9" PIPE LENGTH BLACK...
  • Page 26 ❖ One 45 elbow is allowed for corner installations (24” total length max). ❖ May be used with an Archgard 999-DV-SVK, 999-DV-HTC or 999-DV-STC ❖ SNORKEL. For best venting performance, here are some general venting rules: 1. Use only vent systems and components certified for use with this appliance.
  • Page 27 This appliance will not function without being connected to a proper venting system. This appliance may use 4" & 7" gas flex vents with 3600-DVTR24N-2 listed vent components, Selkirk (Direct-Temp) 4” x 6⅝”” venting or Simpson Dura-Vent 4" x 6⅝"...
  • Page 28 3600-DVTR24N-2 INSTALLATION INSTRUCTIONS TOP VENT HORIZONTAL VENTING Example 1 V Value = 3A (12') = 12' H Value = 4B (8') + 1C (3') = 11' V Value = Total length of all vertical sections in feet. H Value = Total length of all horizontal sections in feet.
  • Page 29 3600-DVTR24N-2 INSTALLATION INSTRUCTIONS Example 1 TOP VENT VERTICAL VENTING V Value = 3A (12') + 1C (3') = 15' H Value = 2B (4') =4' V Value = Total length of all vertical sections in feet. H Value = Total length of all horizontal sections in feet.
  • Page 30 3600-DVTR24N-2 OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION Check that the appliance is properly vented and connected to the gas supply. ❖ Check the logs and branches are properly placed. ❖ ❖ Check all external parts, such as grills, door and control cover are properly attached and fastened.
  • Page 31 3600-DVTR24N-2 OPERATION INSTRUCTIONS START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Set the remote switch to the OFF position. Set the flame adjustment knob to the HI position. Press slightly and turn the control knob  clockwise to the OFF position and wait 5 minutes;...
  • Page 32: Maintenance

    3600-DVTR24N-2 MAINTENANCE CAUTION: Do not conduct maintenance on the appliance while it is operating or while hot CLEANING THE APPLIANCE The exterior surfaces and glass may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
  • Page 33: Troubleshooting

    3600-DVTR24N-2 TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting trouble shooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician.
  • Page 34 3600-DVTR24N-2 TROUBLESHOOTING SYMPTOM ACTION The main burner does not turn 3. Check to make sure the thermostat is set high enough to turn on the on with the pilot lit. (cont’d) appliance. 4. Check that the remote switch or the thermostat is turned on.
  • Page 35: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the authorized Archgard dealer which you purchased the appliance from and provide them with details of the problem and the installation information that the installer filled out at the back of the manual.
  • Page 36 3600-DVTR24N-2 SERVICING REPLACING MAJOR GAS COMPONENTS If any of the major gas components need to be replaced, such as the pilot or the gas valve, we recommend replacing the complete gas component assembly. The assembly is designed to be quickly and easily replaced with minimal inconvenience to the customer.
  • Page 37: Important Information

    3600-DVTR24N-2 IMPORTANT INFORMATION * Please have the installer fill out the installation information for warranty and future reference. APPLIANCE 3600-DVTR24N-2 Top / Rear MODEL NUMBER SERIAL NUMBER • NATURAL GAS • LPG SIT 820 Nova GAS TYPE VALVE TYPE DATE PURCHASED...
  • Page 38 3600-DVTR24N-2 REPLACEMENT PARTS LOCA- Part # Description Unit TION 200-1905 OWNER’S MANUAL, OPTIMA 3600 DVT / DVR 301-0077 ORIFICE, MALE #54 for PROPANE - DRILL TO #54 301-0077 ORIFICE, MALE #43 for NATURAL GAS - DRILL TO #43 307-0056 GLASS, CERAMIC (22 ⅜" x 33 ⅛")
  • Page 39 3600-DVTR24N-2 REPLACEMENT PARTS BURNER ORIFICE BURNER PAN...
  • Page 40 This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use and service, for a “lifetime”.
  • Page 42 POSTAGE WARRANTY REGISTRATION RCHGARD NDUSTRIES 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED 3600-dvtr24n-2 Model # : Serial #: Date Installed: yyyy Name: Address: City: State/Prov: ZIP: Phone: ( _____ ) Dealer's Name &...
  • Page 44 Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com...

Table of Contents