  • Page 3: Introduction

    . A flip-down panel allows the user to wire connections on location . The JB210 series also features an IEPE bias indicator light built into the front panel, which can be used to indicate errors in the field wiring or the sensor .
  • Page 4: Product Dimensions

    Product Dimensions Front View Side View Figure 1. Dimensions Bias Indicator Switch Light Measurement Location Card Data Collector Access (BNC) Input Terminal Strip Options Data Collector Quick Screw Access (2 pin) Connect Terminal Option Option Figure 2. Diagram...
  • Page 5: Mounting Instructions

    Mounting Instructions Stainless steel mounting brackets are included on the enclosure . Wall anchoring screws are not included . Mounting Vibration Brackets Switch Box 0 .31 in ./7 .95 mm (Rear View) Figure 3. Mounting Bracket Placement...
  • Page 6: Conduit Entry

    Conduit Entry If you have purchased a switch box without cable entries provided, you should add your own entry prior to mounting the enclosure . CTC does not recommend putting holes in the top of enclosures as it will cause restricted access to the wire termination connection points and also allow possible moisture ingress .
  • Page 7: Grounding

    Grounding Ensure the shield ground wire on the JB210 Series Switch Boxes is grounded to earth ground . A. Mounting to Earth Ground When mounting JB210 Series Switch boxes to earth ground (such as an I-Beam), no additional steps are necessary, as the enclosure is grounded internally .
  • Page 8 Grounding B. Mounting to non-grounded structure When mounting the switch box to a non-grounded structure, ensure the shield ground wire or customer supplied ground wire is tied to a source of earth ground . Figure 6. Ground Wire Placement...
  • Page 9: Sensor Installation

    Sensor Installation Installation of sensors/signal input cable Feed blunt cut end through the cable entry at the bottom of the enclosure . Note: it is recommended that cables are marked on both ends . For cord grip cable entry, take off the cord grip cover with bushing and run cable through it and into the enclosure, hand tighten cord grip cover to base to prevent damage of cord grip .
  • Page 10 Sensor Installation Locate the appropriate plug (identified by channel number), remove it, and install the wires using a small flathead screwdriver . Push plug back into location . Orientation is as follows: a . Red insulated conductor wire is connected to (+) . b .
  • Page 11 Sensor Installation Insert plug into the appropriate PC board connector and double check to ensure that the cable is going to the correct channel . Note: If your application requires continuous output, the wiring configuration for the JB210 is slightly modified . INPUT #1 INPUT #2 INPUT #3...
  • Page 12: Post Installation Testing

    Post Installation Testing The TM1018 Accelerometer Verification Meter can be used to verify cable conductivity, sensor location and proper wiring connections . The Verification Meter will indicate if the sensor, cable and/or junction box is in working condition . It will also confirm bias voltage of the accelerometer, which will inform you of the operation of the internal accelerometer amplifier .
  • Page 13: Maintenance

    Post Installation Testing The following LED Readout indicates the circuit integrity: Green LED: Normal . Indicates proper connection and an output bias will be given, indicating the health of the sensor (4 – 16 V indicates a healthy accelerometer) . Yellow LED: Open Circuit .