Monaco Installation Guide - Surface Profiles - vJUN16
Place the 10mm spacer into the floor channel and use it to align the vertical wall
2
profile. Push the mitred ends together and use a spirit level to ensure that the wall
profile is plumb vertical.
Mark the screw holes for the vertical profile. Remove the profile, drill 4.5mm holes
and insert the wall plugs.
The Majestic Shower Company Limited
Two North Place, Edinburgh Way, Harlow, Essex CM20 2SL England
Reposition the vertical wall channel and insert the top and bottom screws to hold it
3
in place. Insert the rubber strip into the floor channel. Using suction glass lifters, lift
the glass panel into the channels.
Make sure that the panel is plumb vertical. If necessary, use additional short pieces
of rubber strip in the floor channel to pack it up and take note of their positions. Do
not use more than 3 thicknesses of rubber in total.