Operation Safety Rules

For a correct, safe use of the equipment, please read the following carefully and strictly observe the operation safety rules during your operations.

  • High optical power can cause bodily harm, especially to eyes. Never look directly into the end of the optical transmitter fiber jumper or the end of its active connector.
  • Exercise care if you must bend fibers. If bends are necessary, the fiber bending radius should never be less than 38mm.
  • burn hazardshock hazard
    Power socket overload, broken cables or broken plugs may cause electric shock or fire. Regular check-ups on power supply wires and cables are essential. If any appears damaged, replace at once.
  • Use the power supply adapter provided in the package only. Using other adapters may cause equipment damage or operation failures.
  • Install the equipment in a well ventilated environment without high temperatures or direct sunlight to protect the equipment and its components from overheating, which can result in damage.
  • Power off the equipment in the event of lightning storms. Disconnect all cables connected to the equipment such as power cable, network cable and telephone line to avoid equipment damages caused by lightning stroke.
  • Avoid moisture, dampness and water damage. Equipment exposed to water cannot work normally and can be extremely hazardous due to shorting.
  • Do not lay this equipment on an unsteady base.

Product Introduction

The AN5506-01-A is an FTTH GPON optical network unit with high performance and low power consumption. It provides subscribers with multicast services and enables their access to Internet to cater for the broadband access demands of families. The AN5506-01-A supports the functions as follows:

  • Uses GPON uplink that is compliant with ITU-T G.984 series of standards;
  • Supports the configuration of Ethernet interface rates, working modes, MDI / MDIX autonegotiation mode, and Pause flow control;
  • Supports packet filtering and protection against illegal message attacks; supressess unknown unicast, multicast and broadcast packets;
  • Provides performance statistics on all Ethernet lines;
  • Supports obtaining the user IP address in the DHCP mode, supports reporting the physical position information of Ethernet interfaces through DHCP Option82;
  • Supports obtaining the user IP address in the PPPoE mode, supports the PPPoE+ function for accurate user identification;
  • Supports IGMP snooping protocol;
  • Supports the L2 / L3 wire speed forwarding;
  • Supports the NAT function;
  • Supports the WEB configuration function;
  • Supports the AES-128 algorithm for data encryption of downlink data;
  • Performs various QoS functions: supporting global configuration of queue priority and flexible mapping of 802.1p value of packets;
  • Supports the PQ queue scheduling mode.

Product Type

Product Type

Technical Specification

Type Item Description
Mechanical parameter Dimension 25.5mm × 112mm × 112mm (H × W × D)
Weight 120g approximately
Power supply parameter DC DC 12V/0.5A
Power consumption parameter Power consumption 4W
Environmental parameter Operating temperature -5 ℃ to 45 ℃
Storage temperature -40 ℃ to 70 ℃
Environmental humidity 10% to 95%, non-condensing

Equipment Installation

The AN5506-01-A can be placed on a desk, or hung against the wall.

Desktop mounting

Desktop mounting

Wall-hung mounting

Wall-hung mounting

Interfaces and Connections

Interfaces and Connections

Rear panel

  1. Power switch
  2. Power interface
  3. GE interface
  4. Optical fiber interface

Side panel

  1. Indicator LED switch
  2. Reset button

Indicator LED Description

Indicator LED Description

ON Blinking OFF
  1. Power status LED (green)
The equipment is powered on. The equipment is not powered on.
  1. Ethernet interface status LED (green)
The interface is connected, no data transmission. The interface is receiving / transmitting data. The interface is not connected.
  1. Optical signal status LED (red)
The equipment does not receive the optical signal. The equipment receives the optical signal.
  1. Registration status LED (green)
The ONU is activated. The ONU is activating. The ONU is not activated.

Logging into Web Configuration GUI

  1. Set the IP address and subnet mask of the computer.
  • Select the Obtain an IP address automatically mode (recommended).
  • Set the static IP: The IP address should be in the same network segment as the management IP address of the AN5506-01-A.
    IP address: 192.168.1.X (X is a decimal integer between 2 and 253)
    Subnet mask: 255.255.255.0
  1. Enter http://192.168.1.1 in your browser's address bar. Press Enter to bring up the user login dialog box.
    information Note:
    The factory default management IP address and subnet mask of the AN5506-01-A are:
  • IP address: 192.168.1.1
  • Subnet mask: 255.255.255.0
  1. Enter the username and password in the login dialog box. After being verified, you can access the Web configuration GUI.
    information Note:
    The factory default username and password of the AN5506-01-A are:
  • Username: useradmin
  • Password: user1234

Modifying the Password

  1. Select ManagementUser ManagementMaintenance Account in the navigation bar to open the account maintenance screen.
  2. Enter the username.
  3. Enter the old password.
  4. Enter the new password.
  5. Re-enter the new password to confirm that the passwords entered are identical.
  6. Click Apply to save and apply the new password settings.

information Note:
When using this username to log into the equipment again, you should enter the username and the new password.

Rebooting the Equipment

  1. Select ManagementDevice ManagementDevice Reboot in the navigation bar to open the device rebooting screen.
  2. Click Device Reboot and click Yes in the dialog box that appears to reboot the equipment.

information Note:
After exiting the device rebooting screen, you should wait about 2 minutes before re-logging into the Web configuration GUI of the AN5506-01-A.

FAQs

All indicator LEDs are extinguished after power-on

  1. Check whether the power cable is correctly connected;
  2. Check whether the power supply and the power adapter are normal;
  3. Check whether the power switch on the device's rear panel is in the ON position.

The device fails to work

  1. If the device works abnormally, check whether the power is connected normally or the voltage is not within specifications;
  2. If the equipment is overheated, check the ventilation. Make sure the equipment is not exposed to direct sunshine or is near the heat source.
  1. Check whether the optical fiber is damaged;
  2. Check whether the optical fiber is connected normally to the appropriate interface;
  3. Check whether the received optical power of the ONU is below specifications with an optical power meter;
  4. Check whether the ONU optical module is aged or damaged;
  5. Check whether the device at the central office end is operating normally.

The LAN indicator LED is extinguished

  1. Check if the network cable is damaged or incorrectly connected;
  2. Check if the wiring color-coding scheme of the network cable is incorrect. If incorrect, replace the original network cable with a standard CAT-5 twisted-pair network cable.
  3. Check if the network cable crosses the allowed range.

Logging into the Web page failed

  1. Check the network card configuration, browser version of the user's computer;
  2. Check whether the IP address of the user's computer is correctly configured.
  3. Press down the Reset button to reboot the equipment and restore the factory settings.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download FiberHome AN5506-01-A - GPON Optical Network Unit (ONU) Manual

Advertisement

Need Assistance?

Do you have a question about the GPON AN5506-01-A that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents