Inspecting Parts
Plastic parts: examine for cracking, softening or
discoloring. This may indicate chemical attack of the
material. Defective parts must be replaced. Alternate
material may be required. Contact your supplier or
Pentair Water for assistance.
Metal parts: check for corrosion, scratches, dents,
cracks or other damages to insert ring and spiral
retaining ring.
Other parts: examine for any damage, such as
gouges, chips or cracks, that could affect structural
strength or sealing characteristics. The following are
some examples of defects that may require replace-
ment of the affected part.
End Plug: crac ked, disc olor ed, seal ing
areas damaged(chipped or gouged), threads
stripped or cross-threaded.
Spiral Retaining rings: are the sole means of
end plug retention. Parts bent, corroded,
cracked or damaged in any way must not be
used. Carefully check for hairline cracks.
Refurbishing Shell
1. Using a fine wire brush, remove any large
deposits from locking ring groove in the shell.
2. Using a medium or finer grade of ScotchBrite
and mild soap solution, clean the inside of the
vessel at least 4 inches in from each end.
3. Use clean water to rinse away all loosened
deposits and soap residue.
4. Examine inside of vessel for scratches, gouges,
or other imperfections that could prevent proper
sealing. If such areas exist and leaks are observed
when the vessel is placed back in service , the
shell may need to be replaced.
Distributed by Applied Membranes, Inc. | www.appliedmembranes.com | (760) 727-3711 | USA
Refurbishing Parts
1. Remove any large deposits from metal parts
using a wire brush.
2. Scrub the entire surface with medium grade
3. Rinse parts clean with fresh water and dry.
4. Inspect all parts for serviceability as specified
above.
1. Use a wire brush to remove all foreign matter
from threads on pipe fittings.
2. Apply non-hardening thread sealant or Teflon
tape to fitting and install into end plug. Tighten each
fitting a maximum one quarter-turn past hand
tight; the plastic end plug could be damaged if
fittings are over-tightened.
3. Fit end plug and retaining ring as described in
Replace all parts that cannot be restored to as-new
condition.
Replace any parts showing signs of structural
damage or corrosion.
TM
Seals should be replaced as necessary each time the
vessel is serviced. Any parts that need to be replaced
a r e a va i l a bl e f r om yo ur s uppl i e r or f r om
Pentair Water.
Refurbishing Other Parts
T M
ScotchBrite
until all contaminants are removed.
Remaking Pipe Connections
to End Plug
Replacing the Elements section on page 5 and 6.
Part Replacement
CAUTION
Use of components damaged by corrosion
can cause catastrophic failure.