Pentair Maestro SB-PF-ENS-002D Installation And User Manual

Pentair Maestro SB-PF-ENS-002D Installation And User Manual

Automation
Table of Contents

Advertisement

MAESTRO
AUTOMATION
MAESTRO
C
O
N
T
28/04/2017 15:23:48
Water temp. :+29.0°C
pH:7.8
ORP:607mV
Cond:5264uS 3.28g/l
ESC
1 2 3 4 5
INSTALLATION AND USER GUIDE
IMPORTANT SAFETY INSTRUCTIONS,
READ AND FOLLOW ALL OF THE INSTRUCTIONS,
KEEP THESE INSTRUCTIONS
PENTAIR AQUATIC SYSTEMS
SB-CU-IMP-052H
®
R
O
L
VALID
(Rev. 03/2019)
MAESTRO
®
P R O B E
U N I T
Water temperature
pH
ORP
Conductivity
MAESTRO
SB-PF-ENS-002D
EN
®

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Maestro SB-PF-ENS-002D

  • Page 1 U N I T pH:7.8 ORP:607mV Cond:5264uS 3.28g/l Water temperature Conductivity VALID 1 2 3 4 5 MAESTRO ® SB-PF-ENS-002D INSTALLATION AND USER GUIDE IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS PENTAIR AQUATIC SYSTEMS SB-CU-IMP-052H (Rev. 03/2019)
  • Page 2 Pentair thanks you for your trust and for purchasing a MAESTRO®, a system for water analysis and its off-board display environment, with remote monitoring of your pool via the MAESTRO application from Pentair available in the App store and Play store.
  • Page 3: Table Of Contents

    Summary PRESENTATION > General operation p 01 > Installation example p 02 p 03 > Important safety instructions > Functions p 05 > Supplementary inlets/outlets p 06 > Internet relay, installation and connection p 07 > Internet relay - functioning and connection and account creation p 08 >...
  • Page 4: General Operation

    General operation www. automation - Remote access to information and -piscine.eu INTERNET and remote management of the pool: Internal display Internet box Internet relays Radio relay MAESTRO MAESTRO Control Center Probe Unit 4X Extension 6 inlet/4 outlet option outlets Electrical cabinet - Control of the equipment in the technical room: MAESTRO supplies the dry contacts to which the classic equipment of the technical room is connected (filtration pump, disinfectant...
  • Page 5: Installation Example

    Installation example...
  • Page 6: Important Safety Instructions P

    IMPORTANT SAFETY GUIDELINES, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS GENERAL POINTS - DANGER - INSTALLERS, POOL SPECIALISTS AND OWNERS MUST CAREFULLY READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. - WARNING - Most countries regulate the construction, installation and operation of public swimming pools and spas, and the construction of residential pools and spas.
  • Page 7 - DANGER - DO NOT LET CHILDREN OPERATE THIS EQUIPMENT. - WARNING – Strictly respect the safety and handling procedures from the acid manufacturers, including protective measures for hands, body and eyes during transfer and use of acid. Follow the prescribed safety precautions for handling muriatic acid intended for checking the water pH. Muriatic acid may cause serious physical harm and may damage the swimming pool equipment.
  • Page 8: Functions P

    Functions Filtration control: - By calculating the time according to the pool temperature (automatic mode). - By programming a 24 hour cycle (makes it possible to benefit from off hours). - By integrating the frost protection function (activation of the filtration below 3°C) - By giving priority to the heating, RedOx regulation, or pH (if the value of one of these references falls below the set value, the filtration will start on the next hour, on the hour).
  • Page 9: Supplementary Inlets/Outlets

    Supplementary inlets and outlets - (option with 4X Extension) Requirement for additional connected equipment: - If you need to connect more equipment, the 4X Extension unit can be linked (ref SB-PF-INA-001A, available as an option). Possible connections on the 4 In inlets: - Disabled: Unused inlet, or makes it possible to disable an inlet which was previously used and to leave the connection without any consequences.
  • Page 10: Internet Relay, Installation And Connection P

    However, if the internet relay was installed after MAESTRO, it can be paired via the radio menu, see p 18. SB-SE-BBX-001B Connection 6V 0.8A / IP40 433.445 MHz / MADE IN ITALY Pentair International LLC, Ave. de Sevellin 18, CH-1004 LAUSANNE, Switzerland 1 - Connect one end of the supplied Ethernet...
  • Page 11: Internet Relay - Functioning And Connection And Account Creation P

    INTERNET RELAY - functioning = not connected to the server > Check the power supply, connection of the Ethernet cable and the internet connection. Connected to the server Data transfer in progress Not lit Flashing Initialisation fault or no supply Transmission >...
  • Page 12: Probe Unit, Description P

    The service life of the probes (according to the conditions of use) is around 18 years for the pH probe, 5 years for the RedOx probe and a lifetime for the conductivity and temperature probes. Only Pentair probes are compatible and guarantee proper functioning of the MAESTRO probe unit (see p40). Tighten/loosen the probe bottles.
  • Page 13: Control Center, Description P

    Fuse holder Serial number (1A) SB-PF-ENS-002D SB-SE-TEC-001B Connector cover QC Passed MADE IN ITALY Pentair International Sarl Mfg Year 1234ABCD1234ABCD1234ABCD01 SCAN Avenue de Sévelin 18 230 V 50 Hz~ / IP64 / 16 W Apr-2019 (Removable with a 433.445 MHz...
  • Page 14: Wall Installation Of Maestro Housings P

    Back of devices Control Center Probe Unit Location of fastening screw head Centre axis between both blocking screws and fastening screw Radio antenna Centre axis of two locking screws Pool-ID label 185 mm 185 mm Internet access codes MAESTRO Pool ID: 12 345 ID Key: 1A:2B:33:99 Caps (Do not remove)
  • Page 15: Control Center, Hygiene Of Electrical Connections P

    Hygiene of Control Center electrical connections - The device must be installed by a qualified technician according to valid local regulation - This device is permanently connected. - The power supply to the device is cut by its interrupter, which must be close and must remain accessible at all times.
  • Page 16: Control Center, Settings Basis P

    Control center, basis for settings in an existing installation - RS-485 connections must remain within the building. The 3-position interrupters MAESTRO is connected FILTRATION MAESTRO are kept. ® to a classic electrical FORCED OPERATION 28/04/2017 15:23:48 Water temp. :+29.0°C pH:7.8 ORP:607mV STOP Cond:5264uS 3.28g/l...
  • Page 17: General Electrical/Hydraulic Installation P

    Hydraulic/electrical installation MAESTRO probe unit is supplied with a saddle clamp and a cable gland for the temperature probe. However, the 3 other probes should be placed in a bypass which optimises the quality of the measurements and the service life of the probes (rec. ref. SB-PD-PRO-005B). MAESTRO ®...
  • Page 18: Temperature Probes P

    Water and air temperature probes. MAESTRO is supplied with a temperature probe which is suitable for water. It is possible to mount a second temperature probe for the air temperature used to manage the frost protection process of heated technical rooms.
  • Page 19: Probe Unit, Electrical Connections P

    3 - Connect each pod according to the indicator under each terminal block 4 - Tighten using a 2.5 mm/0.5-0.6 Nm slotted screwdriver 5 - Securely re-tighten the strain relief bushing by hand Only Pentair probes are compatible and guarantee proper functioning of the device.
  • Page 20: Control Center, Filtration, Connections And Settings P

    Control Center, filtration - connection and settings The filtration pump outlet does not supply any power. ! Assembly for classic pumps only. For the VS pumps, see the Speed FC notice! New installation: FORCED OPERATION PHASE (L) EARTH NEUTRAL (N) Existing installation: Parallel connection with the contact of the filtration programmer.
  • Page 21 Control Center, filtration - connection and settings (Cont.) Select current mode: Auto = Automatically calculates the filtration length according to the water temperature. On = Filtration runs 24/7. Off = The filtration is stopped (attention: the antifreeze mode is inactivated). Schedule = The filtration runs during each time period selected in the menu “Schedule Settings”...
  • Page 22: Control Center, Disinfection, Connections And Settings P

    Control Center, connection and configuring a 230-V disinfectant dosing pump at the “Electrolyser” outlet. The electrolyser outlet is valid for any type of disinfection. It is a dry contact and does not supply any voltage. 1 - Connect the cables in accordance with the diagram. 2 - Access the secured Install menu of MAESTRO (on the Menu Settings, press Esc and Valid at the same time for 3 secs).
  • Page 23: Control Center, Ph Pump And Lighting - Connection And Settings P

    Control Center, connection and con guration of an electrolyser. The electrolyser outlet does not supply any power. 1 - Connect the safety switch (flow switch or 3rd electrode of the electrolyser) in series, in accordance with the diagram. 2 - Access the secured Install menu of MAESTRO (on the Menu Settings, press Esc and Valid at the same time for 3 sec).
  • Page 24: Control Center, Lighting - Connection And Settings P

    Control Centerconnection and con guration of lighting. The lighting outlet is a dry contact and does not supply any voltage. New installation: Total lighting power PHASE (L) 12 V < 1600 W below 1,600 W: EARTH NEUTRAL (N) PHASE (L) Total lighting power 12 V >...
  • Page 25: Control Center, Heating Pump - Connections And Settings, Other Alert Messages P

    Control center, connection and configuring a heat pump. The Heating pump outlet is a dry contact and does not supply any voltage. Connection Connection via a contactor via the safety shutdown (flow switch) PHASE (L) EARTH NEUTRAL (N) 1 - Connect the cables in accordance with the chosen diagram. 2 - Set the heating pump to its own maximum temperature set point (MAESTO will manage the set point value to be achieved) 3 - Via Menu Settings >...
  • Page 26: Radio Pairing P

    Pairing of a MAESTRO C.C. to an existing installation This procedure makes it possible to link a MAESTRO C.C. to a MAESTRO P.U. following any device changes. The devices are all initially paired to each other. MAESTRO will therefore take the paired MAESTRO P.U values into account to manage the equipment in the technical room.
  • Page 27: Control Center, Activity, Internal Menus P

    History menu This menu makes it possible to find the daily activity (over the last 64 days) of each connected piece of equipment. 1 - Access the secured MAESTRO current day activity menu by pressing Valid. for 4 sec: > > Access 4 pages of the current day activity by pressing Valid >...
  • Page 28: Navigating The Menus P

    Navigation menus (1/2) - Menu Settings pH/Disinfect./Temp Auto/Off pH+/pH- define Setpoint Priming Disinfectant Auto/Off Setpoint Priming Temperature Auto/off Setpoint Language Language Units (°C/cm and °F/inch) Time Date/Time Radio Register installation Register remote control Reset remote controls - Menu Lighting Manual/schedule/off Colour: 1 Schedule setting - Filtration Menu...
  • Page 29 Navigation menus (2/2) - Install menu Electrolysis/Other Filtration Antifreeze: +3°C ECO=(Standard-30%) Turbo(Standard+30%) Injection time: 15 sec (every 15’) Temperature min.: 3 °C Max. daily volume: 0.2 L (for a 1 litre/h pump) Disinfection Injection time: 15 sec (every 15’) Temperature min.: 3 °C Max.
  • Page 30: Radio Relay - Description

    Grooves for the Serial number clamp collars SB-SE-PER-001C MADE IN ITALY 4 x LR6 1.5 V / IP65 433.445 MHz Pentair International LLC, Mounting holes Av de Sevellin 18, CH-1004 LAUSANNE, Switzerland VIEW FROM ABOVE VIEW FROM BELOW OPEN Battery holder contact...
  • Page 31: Radio Relay - Installation

    RADIO RELAY - installation of batteries (4xLR6 - 1.5 V) The service life of the batteries supplied is more than a year (depending on the conditions of use). Since the radio relay is exposed to very high heat, using high-quality alkaline batteries resistant to temperatures up to +70 °...
  • Page 32: Indoor Display - Presentation

    INDOOR DISPLAY - Presentation The remote indoor display provides information on all the parameters (updated every 15 minutes) of the water quality and comfort (temperatures, UV). Intended for internal use, pre-programmed alerts make it possible to check the chemical balance of the water at a glance without needing to perform cumbersome analyses at the edge of the tank.
  • Page 33: Indoor Display - Reading And Intervention Following A Message P

    - Selection of units Mode alarm : - Customisation of alarm values SB-SE-DOM-001B MADE IN ITALY 4 x LR6 1.5 V / IP40 433.445 MHz Pentair International LLC, Av de Sevellin 18, CH-1004 LAUSANNE, Switzerland calib on alarm Identification tag Serial number...
  • Page 34: Indoor Display - Reading And Intervention Following A Message

    INDOOR DISPLAY - reading and intervention following a message Temperatures The indoor display provides the following, alternating values (in °C or °F, see p23): - The air temperature accompanied by a symbol e.g.: The air temperature is 28.5 °C - The water temperature accompanied by a symbol Respecting the north-south direction of the radio relay improves the measurement precision of the air temperature.
  • Page 35: Indoor Display - Ph Reading P

    INDOOR DISPLAY - pH reading The pH is a scale (without any units) measuring the acidity (0 to 7) or the alkalinity (7 to 14) of the pool. The The pH pH is the concentration of the hydrogen ions. For a swimming pool, the ideal pH which is generally advised is close to 7.3 (to be confirmed by your swimming pool supplier according to your installation).
  • Page 36: Indoor Display - Conductivity Reading P

    INDOOR display - Conductivity reading Ability of the water to permit passage of an electrical current; the conductivity is proportional to the The pH concentration of dissolved minerals (which partially come from water treatment products). The µS value reveals “the age of your pool' s water”. µS/ g/L correspondence : 1,000 µS = 0.63 g/L 1 g/L = 1,587 µS Conductivity at 25 °C (µS/cm)
  • Page 37: Indoor Display - Redox Reading P

    INTERNAL display - RedOx reading Disinfectant concentration level (chlorine, bromine, active oxygen, etc.) present in the pool. The pH Keeping within 650 mV and 750 mV is recommended for this 'disinfection power' measurement. The oxidation reduction potential indicates the oxidiser quality present in the water. It is the result of the disinfectant quantity/pollution quantity ratio.
  • Page 38 INDOOR DISPLAY - reading and intervention following a message Operating modes The alarm (see p32) and calibration modes (see p34) correspond to the switch position on the back of the indoor display. Radio mode signifies that the radio is in learning mode for a new element in the MAESTRO network.
  • Page 39: Indoor Display - Radio Mode P

    RADIO MODE - Add a radio relay and/or indoor display The elements which constitute a MAESTRO set are paired with a unique radio code which prevents any risk of interference with other MAESTRO units (in the vicinity) as a factory setting. In an existing MAESTRO system, this RADIO mode makes it possible to add: - A second relay radio to compensate for difficult situations in terms of radio range (elevation, very long distances, etc.) - A second indoor display (“No.
  • Page 40: Indoor Display - Alarm Mode P

    RADIO MODE - Re-learning of the original indoor display The elements which constitute a MAESTRO set are paired with a unique radio code which prevents any risk of interference with other MAESTRO units (in the vicinity, several pools close together, etc.) as a factory setting. If the original display is lost or replaced, this RADIO mode makes it possible to recognise it in the existing MAESTRO network.
  • Page 41 ALARM MODE - Modification of the alarm set point values This mode makes it possible to modify the set point value of: - The upper pH alarm (factory setting 7.9) - The lower pH alarm (factory setting 6.7) - The upper conductivity alarm (factory setting 1,200 µS) - The lower conductivity alarm (factory setting 50 µS) - The upper RedOx alarm (factory setting 800 mV) - The lower RedOx alarm (factory setting 500 mV)
  • Page 42: Indoor Display - Calib. Mode, Change Of Unit And Voluntary Correction Of Values P

    ALARM MODE - Modification of the alarm set point values Lower conductivity limit alarm Upper conductivity limit alarm RedOx alarm lower limit RedOx top limit alarm > Put the switch back in ON mode To reset all the device values to the factory settings, press "reset" for 4 sec with a paperclip on the back of the indoor display.
  • Page 43: Indoor Display - Calibration Of Ph And Redox Probes P

    CALIB MODE - Change of units & voluntary correction of values Despite calibration of the measurement sensors, a value may be out of step with another measurement marker (usual thermometer, etc.). For this, you have the option of voluntarily correcting some values. - This mode makes it possible to modify the units of: - The air and water temperature (factory setting °C) - The water height (factory setting: cm)
  • Page 44: Maintaining Ph And Redox Probes And Wintering P

    Due to its nature, a pH probe needs to be regularly re-calibrated (ideally before the season). If this has been forgotten, a “probe check” message will appear on the screen of the Control Center. The Pentair pH probe is available as a spare part from your Pentair dealer.
  • Page 45: Radio Relays And Indoor Display And Spare Parts P

    MAINTENANCE - Cleaning of the pH or ORP probe. Deposition of scale or suspended elements in the pool may occur. The probes are fragile measuring parts, they need to be carefully cleaned. In particular, do not scratch the platinised surfaces of the electrodes of the conductivity probe.
  • Page 46: Updating Of Maestro Probe Unit P

    (leaves, stains, etc.). TECHNICAL SUPPORT Your official Pentair distributor will support you with any information needed for optimal use of your MAESTRO. Answers to FAQs are available at http://www.domotique-piscine.eu/faq. You can ask your questions to the following email address: techsupport.poolemea@pentair.com SPARE PARTS (ref) The original parts required to maintain your Pentair device are available from your dealer.
  • Page 47: Technical Characteristics And Guarantee P

    MAESTRO probe unit: How to update the internal firmware 1.1 - Unzip the MAESTRO Probe UnitXXX.zip file to obtain the Pxxxo.bin. file. recognised 1.2 - Copy the Pxxxo.bin file to the main folder of the USB stick formatted to FAT 16 or FAT 32. 2.1 - Remove the flexible blue cover of the Control Center and the Probe Unit.
  • Page 48: Redox/Ph/Free Chlorine Ratio P

    Variations in the RedOx (ORP) according to the pH and the chlorine rate in water without a stabiliser at a temperature of 18°C.
  • Page 52 Ave. de Sevellin 18, CH-1004 - LAUSANNE, Switzerland Copyright – Limited Licence: except as speci cally permitted herein, no portion of the content of this document may be reproduced in any form or by any means without the prior written permission of Pentair International SRL.