National Instruments NI Vision CVS-1456 User Manual page 53

Hide thumbs Also See for NI Vision CVS-1456:
Table of Contents

Advertisement

Appendix A
Troubleshooting
Error When Configuring IP Settings for the NI CVS-1450 Device
Status of NI CVS-1450 Device in MAX and Vision Builder AI is
No Software Installed
No Camera Found
NI CVS-1450 Series User Manual
Another device on the network is using the IP address assigned to the
NI CVS-1450 device. Either remove or reconfigure the other device, or
reconfigure the NI CVS-1450 device IP address.
The DIP switch settings on the NI CVS-1450 device may be invalid,
such as all switches set to the ON position. Change the DIP switch
settings and reset the NI CVS-1450 device by pressing the RESET
button on the NI CVS-1450 device for at least two seconds.
The CVS-1450 device is configured to acquire an IP address
from a DHCP server, but no DHCP server is available. After three
unsuccessful attempts to acquire an IP address from a DHCP server,
the CVS-1450 device will reboot and enter an unconfigured state.
In the unconfigured state, the CVS-1450 device will have an IP address
of
and the LabVIEW Real-Time engine will not load. In the
0.0.0.0
unconfigured state, the CVS-1450 device has network connectivity. If
the CVS-1450 device is on the same subnet as the host computer, then
refreshing the list of remote devices in MAX or Vision Builder AI will
cause the CVS-1450 device to appear with an IP address of
Use MAX or Vision Builder AI to reconfigure the CVS-1450 device IP
address. Then reboot the CVS-1450 device.
The NI CVS-1450 device cannot be configured if the subnet mask or IP
address is incompatible with the network settings. Verify that the values
entered for all network parameters are valid.
Install application and driver software on the NI CVS-1450 device. Refer
to Getting Started with the NI CVS-1450 Series Compact Vision System for
installation instructions.
Verify that the total power requirements of the cameras do not exceed
the power the NI CVS-1450 device provides on the IEEE 1394 bus. Verify
that the cameras comply with the IIDC Digital 1394-based Camera
Specification, Version 1.30.
A-2
.
0.0.0.0
ni.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ni vision cvs-1450 series

Table of Contents