Page 1
WE-EF LEUCHTEN Installation and Maintenance Instructions Wall Luminaires Surface Mounted RLS410 LED RLS420 LED Do not open during installation Surge Protection This product is factory-sealed. This product features built-in surge protection circuitry in compliance with Refer to the instructions contained in this applicable standards.
Page 2
Wall Luminaires Surface Mounted RLS410 RLS420 IP66, IK08. Class I, ta = 40°C Tool required – Screwdriver TX25...
Light Source Maintenance Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. Do not use high-pressure cleaners. In case of component failure due to abnormal circumstances or at end of life, replacement must be carried out Warning: Do not open luminaire while mains supply is switched on.
Installation The product must be installed and maintained by a building/construction and/or electrical regulations and relevant legislation. Warning: Switch off mains electrical supply prior to installing and connecting the luminaire. Notice: than the original manufacturer, then the warranty will no longer be valid and shall become the full respon- sibility of the modifying person/organisation.
B by loosening screws C. Pull off terminal connector D. 3) Check that rating shown on luminaire label conforms with mains electrical supply. Drill relevant holes F and insert nylon plugs G (not supplied by WE-EF). 05/19 IP66 RLS420-LED 220-240V/50-60 Hz 131-XXXX SOE XXXXXXX LED 3000K 18W item no.
Page 6
5) Feed supply cable G (and second cable H for through wiring, if required) through packing ring I and pressure screw(s) J A in position. The pre-installed packing ring I is suitable for cable diameters 7 to 9.5 mm. For larger cable diameters (9 to 12 mm) use the auxiliary packing ring supplied.
Page 7
7) Connect leads of main supply cable G (and second cable H for through wiring, if required) to respective terminals of socket K: a) ON/OFF (L = Phase, N = Neutral, b) 1-10 V/DALI (L = Phase, N = Neutral, = Earthing) = Earthing, DA/DA = DALI control line, D–/D+ = 1-10 V control line).