Programming - Winston Industries Collectramatic 8000 Series Use & Care Manual

Fryer control 8 channel very low pressure/temperature 4 head & 6 head
Table of Contents

Advertisement

PROGRAMMING THE LP46 AND LP56 COLLECTRAMATIC ® FRYERS
Note: the instructions below will refer to key numbers. There are 16 keys on the
control panel (2 of them are hidden). There are 8 keys along the top row and 8 along
the bottom row. The top row represents keys 1 through 8 and the bottom row keys 9
through 16 - keys 14 and 15 are hidden. Refer to the control illustration below.
FRYER CAPACITY
To accommodate the heat rate differences between a 4-head fryer and a 6-head
fryer, the controller needs to be programmed accordingly.
Configure for 6-Head: With the power switch in the OFF position press and hold
keys 9 and 10 while simultaneously turning ON the power switch.
Configure for 4-Head: With the power switch in the OFF position press and hold
keys 15 and 16 while simultaneously turning ON the power switch.
ACCESS MODE
LP fryers can be programmed in one of two modes - Easy Access or Restricted
Access. Restricted access requires the operator to enter an access code (special
key sequence) to be able to re-program times and temperatures for the channels.
Easy Access (default mode)
Allows programming of any channel by pressing the cook temp and cook time keys
to the settings you desire.
1.
Select the channel you want to program by pressing the channel key (top row of
keys 1 through 8) until red light appears above the channel. Programming may
be done with fryer on or off (fryer must be connected to power source).
Collectramatic ® Fryers – Very Low Pressure/Temperature – LP46, LP56
Hidden
Hidden
key 14
key 15

PROGRAMMING

INSTRUCTIONS
www.winstonind.com
800-234-5286
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Collectramatic lp46Collectramatic lp56