SET UP

INSTRUCTIONS
ASSEMBLY OF THE LP46 AND LP56 COLLECTRAMATIC ® FRYERS
CAUTION: Prior to using appliance for the first time, perform the daily cleaning
procedure listed on pages 25 through 27.
Before beginning the assembly process, wipe out cookpot
and collector with damp, lint-free towel. This removes any
dust or debris that may have accumulated. Never use
water in the fryer.
1. After uncrating your fryer, you will find two sets of
2. Lubricate the smaller o-ring with cooking oil and
3. Install collector in bottom of fryer and gently tap with
4. Check to determine that drain valve is closed.
5. Fill with cooking oil to one inch below Minimum fill line. Oil will expand as it is
6. Lubricate large o-ring with cooking oil and install in groove around edge of lid.
7. Check to be sure that main vent assembly and dead weight are in place at rear
www.winstonind.com
800-234-5286
12
o-ring gaskets – two large and two small.
install in groove at top of collector (see Figure 1).
stirring tool until it seats into place.
FIGURE 2
heated. Check oil level again once it has heated to cooking temperature to verify
that oil level is between Minimum and Maximum marks.
of fryer.
Collectramatic ® Fryers – Very Low Pressure/Temperature – LP46, LP56
FIGURE 1
Drain Valve closed
Rotated clockwise
up and back as far
as handle will move.
To open, pull
counter-clockwise
forward and down.