Fixing brackets
Screw the fixing brackets (A) into the holes
on the sides of the bottom casing to
properly fasten the hob to the structure.
Do not use silicone to secure the
hob. This would make it impossible
to remove the hob, if necessary,
without damaging it.
Hob seal
To prevent leakage of liquid between the
frame of the hob and the countertop, place
the adhesive seal provided along the entire
outer edge of the hob before assembly.
Installation

5.4 Gas connection

Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.
• The adjustment conditions for this
appliance are shown on the gas setting
label.
General information
Connection to the gas mains can be made
using a rigid copper pipe or a continuous
wall steel hose in compliance with the
provisions established by the applicable
standard.
For supplying it with other types of gas, see
chapter ""Adaptation to different types of
gas"". The gas inlet connection is threaded
½" external gas (ISO 228-1).