Download Print this page

Garland EdgeSafe P10GMSBPE Quick Start Manual

Bypass network tap
Hide thumbs Also See for EdgeSafe P10GMSBPE:

Advertisement

Quick Links

EdgeSafe​
TM
Bypass Network TAP 
Quick Start Guide By Garland Technology
P10GMSBPE / P10GSSBPE
Garland Technology: Bypass System
Firmware Rev Level: ​ 1 .1.11
 
Office: 716-242-8500
garlandtechnology.com/support
garlandtechnology.com
 
 

Advertisement

loading
Need help?

Need help?

Do you have a question about the EdgeSafe P10GMSBPE and is the answer not in the manual?

Questions and answers

Summary of Contents for Garland EdgeSafe P10GMSBPE

  • Page 1 EdgeSafe​ Bypass Network TAP  Quick Start Guide By Garland Technology P10GMSBPE / P10GSSBPE Garland Technology: Bypass System Firmware Rev Level: ​ 1 .1.11   Office: 716-242-8500 garlandtechnology.com/support garlandtechnology.com    ...
  • Page 2 EdgeSafe | ​ P 10GxxBPE  Copyright © 2020 Garland Technology, LLC. All rights reserved. No part of this document may be reproduced in any form or by any means without prior written permission of Garland Technology, LLC. The Garland Technology trademarks, service marks ("Marks") and other Garland Technology trademarks are the property of Garland Technology, LLC.
  • Page 3: P10Gxxbpe Dashboard

    - Link/Activity LED Port 4 H/M Port 3 - Heartbeat missed if placed in bypass mode H/M Port 4 - Heartbeat missed if placed in bypass mode Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 4: P10Gxxbpe System

    - enter 60 to 3600 seconds, default 300 Save - select to save any changes Cancel - select to return to general system settings Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 5 - enter the desired DNS1 server DNS2 - enter the desired DNS2 server Save - select to save any changes Cancel - select to return to network settings Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 6 - displays the current udp/tcp port, default 514. If desired a new port number may be entered Save - select to save any changes Cancel - select to return to syslog configuration Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 7 Restart Import - select to choose a different configuration file or cancel Configure - select to load the configuration file on the unit Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 8 Provides the ability to reboot the unit. This will affect traffic for @ 15 seconds. Reboot - select to reboot the unit Reboot - select to reboot the unit Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 9: P10Gxxbpe Port Info

    USER GUIDE   EdgeSafe | ​ P 10GxxBPE  P10GxxBPE Port Info Select Port Info to display or change port configuration and display port statistics. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 10 Not all SFPs or QSFPs support this function Split - non-functional Save - select to save any changes Refresh - select to refresh the port configurations Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 11 - displays the number of transmit packet errors Refresh - select to update the port statistics Clear - select to clear and refresh the port statistics INT10G8xx56 Modes Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 12: P10Gxxbpe Tap Modes

    Select Bypass Taps to display or change the bypass tap settings. Displays the current mode. The P10GxxBPE supports the following modes, Bypass, Span, Span (Packet Inject), Breakout, Filter and Aggregate. Bypass Mode - Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 13 Provides access to display or change the bypass tap settings, the Heartbeat per second rate and the number of lost heartbeats Displays the current tap status. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 14 To change the tap’s settings, place the cursor on the tap and double press the left mouse button. The tap panel will appear. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 15 - select to save changes to the tap settings Cancel - select to disregard changes to the tap settings and return to bypass tap Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 16 Cancel - select to disregard changes or keep original settings and return to the tap display Span Mode - Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 17 1 is sent to span port 2, but not span ports 3 and 4. Span (Packet Inject) Mode - Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 18 2, but not span ports 3 and 4. Traffic from packet inject port 2 is sent to network port 1, but not from packet inject ports 3 or 4. Breakout Mode - Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 19 1 is sent to network port 2 and ingress traffic from network port 2 is sent to network port 1, but there will be no aggregate traffic to ports 3 or 4. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 20 - select Packet Broker Provides access to create, display or change, Filter Templates, Config Maps, Filters or Stats. Displays the current packet broker configurations. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 21 Delete (select all) - select to delete selected config maps Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 22 - select to create a new filter template The Create New Filter Template panel will appear. Filter templates may be created as pass all, pass by or deny by. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 23 RED X to delete. The filter template will also be presented on the create config map display. Create a Config Map - Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 24 - select to save changes Reset - if editing an existing config map, select reset to reset changes back to original config map Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 25 Filters may be selected and moved up or down to change their priority. Filters may be modified by selecting the GREEN filter icon. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 26 Egress panel, select the RED X. If more than one port is selected for the egress a copy of the traffic from the ingress port(s) will be sent to each egress port. Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.
  • Page 27 For questions, please contact Garland Technology Support at: 8AM-9PM (CST) Monday - Friday (Except for observed US Holidays) Tel: 716.242.8500 Online: ​ g arlandtechnology.com/support Garland Technology | 716.242.8500 | ​ g arlandtechnology.com/support Copyright © 2020 Garland Technology, LLC. All rights reserved.

This manual is also suitable for:

Edgesafe p10gssbpe