SECTION 8: MAINTENANCE
Procedure
1. Unplug the Power Supply Enclosure from the
electrical outlet.
2. Drain the vessel completely.
3. Remove UV lamp(s). See Page 17 for instructions.
4. Using the white retaining nut tightening tool included
with the UV system, unthread the Quartz Sleeve
Retaining Nut from the male-threaded Quartz Sleeve
Module located on the QSM Faceplate. Once the
Quartz Sleeve Retaining Nut is unthreaded the open-
end of the quartz sleeve will be exposed.
5. Wearing clean cotton or silicon gloves gently slide
the quartz sleeve from the UV vessel. DO NOT use
pliers or any tools that may break the quartz sleeve.
6. Remove the Quartz Sleeve Gasket and continue
removing the quartz sleeves until all are removed
from the vessel. Place quartz sleeves on a safe, level
surface to avoid breakage.
7. Inspect all quartz sleeves for cracks, chips and
scaling. If required, clean the quartz sleeve(s). See
Page 19 Quartz Sleeve Cleaning. Replace damaged
(cracked, chipped) quartz sleeves.
WARNING: If a sleeve nut is removed when there
is dynamic water pressure inside the UV system, the
lamp sleeve will eject from the end plate with enough
force to cause personal injury.
WARNING:
SERVICING WHILE
PRESSURIZED CAN CAUSE
SEVERE INJURY.
LOCK OUT SOURCE AND RELIEVE
PRESSURE BEFORE SERVICING.
BioShield® PRO UV System Installation and User's Guide

Quartz Sleeve Cleaning

Purpose
To manually check and clean quartz sleeve(s).
Frequency
When required, at least once annually.
Parts and Equipment Required
• Cleaning Solution of Muriatic Acid and Water (1:4
ratio)
• Acid-Proof Bucket
• Clean Cloth
• Acid-Proof Drop Cloth
• Acid-Resistant Gloves
• MSDS Sheet
• Personal Protective Equipment
General risk due to pressurized piping and UV
vessel!
General risk due to caustic cleaning agent!
Quartz Sleeves are fragile and potentially
dangerous if broken. Handle with care.
First Aid Measures:
In case of skin exposure, to cleaning agent, remove by
washing with soap and water immediatel
In case of eye exposure to cleaning agent wash eyes
for several minutes with water and contact a physician
immediately.
In case of ingestion of cleaning agent contact physician
immediately.