SECTION 5: UV LAMP INSTALLATION
Lamp Field Safety Cover Installation
Purpose
To instruct the operator how to properly install the

Lamp Field Safety Cover.

Frequency
Required anytime the lamp field is accessed.
Parts and Required Equipment
• Lamp Field Safety Cover
• Pliers
• Personal Safety Equipment
General risk due to electricity.
Procedure
1. With the UV lamps and lamp cables installed hand
loosen the four Safety Cover Retaining Screws from
the QSM Faceplate so they have approximately 3/8"
of clearance between the head of the screw and the
QSM Faceplate.
2. The Lamp Field Safety Cover uses a twist-lock
attachment method that can only be installed one
way. Take the cover assembly with the cable slot
facing downward and align the four slotted keyways
on the cover's flange face with the retaining screws
on the QSM Faceplate. Then place the cover over
the screws and turn counterclockwise to engage the
retaining screws.
3. Once the cover is in place, tighten the four Retaining
Screws down until the cover is snugly held in place.
4. With the cover installed on the vessel, connect the
Lamp Field Safety Cover cable that is attached to
the power supply to the connector that is located on
the end of the Safety Cover.
NOTE: The Lamp Field Safety Cover must be installed
onto the vessel with its respective cable, located
on the Power Supply Enclosure, properly
connected to its respective port on the Safety
Cover. Removing the Lamp Field Safety Cover
or the cable connection will automatically shut
off the UV system's lamp field and generate an
alarm signal.